Toshiba A60 S1591 Maintenance Manual - Page 102

Diagnostic Programs, 5 System Test, Speed Change Comparison, Expected Minimum Speed Change

Page 102 highlights

3 Diagnostic Programs 3.5 System Test Speedstep is a kind of energy-saving running mode that is supported by the Pentium III or above. This test item is to check whether the CPU supports Speedstep function according to the change of the CPU work frequency in different power supply mode. In this test item, the user is requires to operate on the screen prompted. Below is the parameter dialog window of CPU Speedstep test item: Speed Change Comparison-When choosing 'No', system only reports the CPU speed at the different power supply. Otherwise, it will compare the CPU speed at High Speed and Low Speed. Whether the difference between the two speeds is greater than the value specified in 'Expected Minimum Speed Change', system will report 'PASS', otherwise 'FAIL'. Expected Minimum Speed Change-Specify the minimum change range of CPU speeds under High Speed and Low Speed. 7. MMX The test item is to confirm whether the CPU supports MMX instructions. Subtest 02 Boards 1. DMA Controller This test item is to check whether the DMA controller works normally. 2. Interval Timer This test item is to check whether the Interval Timer (18.2Hz, 55ms) works normally. 3. Clock/Calendar 32 dynabook AX/Satellite AW2/Equium A60/Satellite A60/ Satellite Pro A60 A65 Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262

3
Diagnostic Programs
3.5 System Test
32
dynabook AX/Satellite AW2/Equium A60/Satellite A60/ Satellite Pro A60 A65
Maintenance
Manual
Speedstep is a kind of energy-saving running mode that is supported by the
Pentium III or above.
This test item is to check whether the CPU supports Speedstep function
according to the change of the CPU work frequency in different power
supply mode. In this test item, the user is requires to operate on the screen
prompted.
Below is the parameter dialog window of CPU Speedstep test item:
Speed Change Comparison
—When choosing ‘No’, system only reports
the CPU speed at the different power supply. Otherwise, it will compare
the CPU speed at High Speed and Low Speed. Whether the difference
between the two speeds is greater than the value specified in ‘Expected
Minimum Speed Change’, system will report ‘PASS’, otherwise ‘FAIL’.
Expected Minimum Speed Change
—Specify the minimum change range
of CPU speeds under High Speed and Low Speed.
7.
MMX
The test item is to confirm whether the CPU supports MMX instructions.
Subtest 02 Boards
1.
DMA Controller
This test item is to check whether the DMA controller works normally.
2.
Interval Timer
This test item is to check whether the Interval Timer (18.2Hz, 55ms) works
normally.
3.
Clock/Calendar