Xerox C2424 Service Manual - Page 205
Media Path Motor, Tray 2, Tray 3, Tray 4, Lift Motor
UPC - 095205676532
View all Xerox C2424 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 205 highlights
Media Path Motor This test turns on the media path motor and runs it very slowly for one revolution. R# Definition Typical Value Actions 0 Motor fe ripple (ticks) .4 to 1.3 Reports amount of variation of the motor following error over the recording interval. 1 Motor fe average (ticks) 0.8 to 2.0 Reports the motor following error average value of the recording interval. 2 Motor drive voltage 4 to 10 ripple (volts) Reports amount of variation of the motor drive voltage over the recording interval. 3 Motor drive voltage -5 to 0 (volts) Reports the motor drive voltage average value of the recording interval. 4 Motor drive power ripple (watts) 0.8 to 6 Reports amount of variation of the motor drive power over the recording interval. 5 Motor drive power average (watts) 1.9 to 7 Reports the motor drive power average value of the recording interval. Tray 2, Tray 3, Tray 4, Lift Motor This test turns on the specified motor and runs it at constant velocity for approximately 20 revolutions while recording drive data. The test is the same for each motor. Requesting a test for a 525-sheet feeder that is not installed will generate an "Option Not Detected" message. R# Definition Typical Value Actions 0 Motor Peak Power MFG (watts) Only 1 Motor Average Power (watts) MFG Only 2 Brake Average Power (watts) MFG Only Reports max amount of motor power over the run interval. Reports the average motor drive power over the last half of the run interval. Reports the average motor brake power over the stop with brake interval. General Troubleshooting 4-47