Yamaha MMP1 MMP1 Operation Manual [English] - Page 20
Speaker Matrix screen
View all Yamaha MMP1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
4. Screens 4-1-5. Speaker Matrix screen This screen is used for routing input signals and speakers. NOTE • You can use this screen when logged in as an "Administrator" or "Advanced User." • Cells with black backgrounds can be used in the "Speaker Matrix" tab of the "Scene" tab on the Settings screen when logged in as an Administrator. • This matrix is 32x32 when the MMP1's sample rate is 96 kHz or less, and 16x16 when the MMP1's sample rate being used is higher than 96 kHz. You can change the sample rate in the "MISC" tab of the "Scene" tab on the Settings screen. Speaker Matrix Out Displays Speaker Matrix Out names Speaker Matrix In For selecting input sources, and adjusting the levels of the selected input sources Speaker matrix Click to turn Send on (purple) or off from Speaker Matrix In to Out NOTE Refer to page 60 when configuring bass management. Speaker Matrix In Type Trim Source For selecting speaker matrix input sources. NOTE The same items can be configured on the "Input Patch" tab on the Patch screen. The input type to the speaker matrix ("Monitor" or "LFE") will appear here. NOTE You can set the Type (CH Type) in the "Speaker Matrix" tab of the "Scene" tab on the Settings screen. Double click or use the mouse wheel to adjust input levels. Out-of-range values entered will be corrected to the maximum or minimum value allowed. NOTE When the Type (CH Type) is "LFE," and the "LFE Trim" button in the "Monitor" section on the Sub screen is set to on, the LFE Trim Level will be added to the input value. MMP1 Operation Manual 20