Yamaha MMP1 MMP1 Operation Manual [English] - Page 37
-8i. Global tab/GPI
View all Yamaha MMP1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
4-1-8i. Global tab/GPI 4. Screens GPI In GPI Out Set the Function and the Trigger for GPI [INPUT] connector pins 1-16 on the MMP1 unit. The following four Trigger types are available. High Executes the Function when the input voltage is High. Low Executes the Function when the input voltage is Low. On Edge Executes the Function when the input voltage changes from Low to High. Off Edge Executes the Function when the input voltage changes from High to Low. Set the Function and the Behavior for GPI [OUTPUT] connector pins 1-10 on the MMP1 unit The following three Behavior types are available. Make Connects contacts within the MMP1. The voltage of the GPI device at the connection destination becomes Low. Break Opens contacts within the MMP1. The voltage of the GPI device at the connection destination becomes High. Pulse Changes the voltage from Low to High, and then reverts back to the Low state after maintaining a High voltage for around 250 ms. MMP1 Operation Manual 37