ZyXEL P-320W User Guide - Page 122

SNMP Screen

Page 122 highlights

P-320W User's Guide • Get - Allows the manager to retrieve an object variable from the agent. • GetNext - Allows the manager to retrieve the next object variable from a table or list within an agent. In SNMPv1, when a manager wants to retrieve all elements of a table from an agent, it initiates a Get operation, followed by a series of GetNext operations. • Set - Allows the manager to set values for object variables within an agent. • Trap - Used by the agent to inform the manager of some events. 11.3.1 Supported MIBs The Prestige supports MIB II that is defined in RFC-1213 and RFC-1215. The focus of the MIBs is to let administrators collect statistical data and monitor status and performance. 11.3.2 SNMP Traps The Prestige will send traps to the SNMP manager when any one of the following events occurs: Table 52 SNMP Traps TRAP # TRAP NAME 0 coldStart (defined in RFC-1215) 1 warmStart (defined in RFC-1215) 4 authenticationFailure (defined in RFC-1215) 6 whyReboot (defined in ZYXEL- MIB) 6a For intentional reboot : 6b For fatal error : DESCRIPTION A trap is sent after booting (power on). A trap is sent after booting (software reboot). A trap is sent to the manager when receiving any SNMP get or set requirements with the wrong community (password). A trap is sent with the reason of restart before rebooting when the system is going to restart (warm start). A trap is sent with the message "System reboot by user!" if reboot is done intentionally, (for example, download new files, CI command "sys reboot", etc.). A trap is sent with the message of the fatal code if the system reboots because of fatal errors. 11.4 SNMP Screen To change your Prestige's SNMP settings, click the Remote MGMT link under Management, and the SNMP tab. The screen appears as shown. 122 Chapter 11 Remote Management Screens

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215

P-320W User’s Guide
122
Chapter 11 Remote Management Screens
Get - Allows the manager to retrieve an object variable from the agent.
GetNext - Allows the manager to retrieve the next object variable from a table or list
within an agent. In SNMPv1, when a manager wants to retrieve all elements of a table
from an agent, it initiates a Get operation, followed by a series of GetNext operations.
Set - Allows the manager to set values for object variables within an agent.
Trap - Used by the agent to inform the manager of some events.
11.3.1
Supported MIBs
The Prestige supports MIB II that is defined in RFC-1213 and RFC-1215. The focus of the
MIBs is to let administrators collect statistical data and monitor status and performance.
11.3.2
SNMP Traps
The Prestige will send traps to the SNMP manager when any one of the following events
occurs:
Table 52
SNMP Traps
TRAP #
TRAP NAME
DESCRIPTION
0
coldStart (defined in
RFC-1215
)
A trap is sent after booting (power on).
1
warmStart (defined in
RFC-1215
)
A trap is sent after booting (software reboot).
4
authenticationFailure (defined in
RFC-1215
)
A trap is sent to the manager when receiving any
SNMP get or set requirements with the wrong
community (password).
6
whyReboot (defined in ZYXEL-
MIB)
A trap is sent with the reason of restart before
rebooting when the system is going to restart (warm
start).
6a
For intentional reboot :
A trap is sent with the message "System reboot by
user!" if reboot is done intentionally, (for example,
download new files, CI command "sys reboot", etc.).
6b
For fatal error :
A trap is sent with the message of the fatal code if the
system reboots because of fatal errors.
11.4
SNMP Screen
To change your Prestige’s SNMP settings, click the
Remote MGMT
link under
Management
, and the
SNMP
tab. The screen appears as shown.