Brother International BAS-760 Instruction Manual - English - Page 26
operation
View all Brother International BAS-760 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
ID Test operation * When using a new sewing clamp assembly with user's own program, conduct a test operation to ensure that the needle will not contact sewing clamp. bather BAS-760 MODE 7.0UMLIMG PROGRAM NO. t*ent9 1PREAD MONITOR fliNkt ft SPEED 7.0 lit ,9 M.L.WW POWER 22P. TEST NMI LAM WwWW STEP 6 FLOPPY O© KEMW. 0FOOT O X1000 C.1/018 BOBBIN CHANGE START 0 SAT9A"C1K3ERON•OFF TAIth,>9 BOBBIN COUNTS 99199- M! COUNTER DEC FAT FAST 289:171,' STEP BACK • theLPOwS FOLDER RESET 0 O WW- WD- P ALARM CODE D 25PARIL EM STOP 0 O C 0 / READ 1W7SM WM PIECE COUNTER O 1. Apply air pressure and turn on the power switch. 2. Set up PROGRAM No. digital switch 0 to match the folding group assembly number with the program data number and then press FLOPPY button ea. Check if the display matches the folding assembly number. 3. Select MANUAL on MODE switch ®. 4. Press TEST button 0 and the lamp will come on. 5. Depress and release the right foot switch O. The main material will be clamped. 6. Depress the right foot switch ® once more and keep it pressed down. The label can then be set. If the pedal is released, the label attachment device will enter standby mode. (If the right foot switch 0 is depressed once more, the label can then be set, and if it is released, the machine will enter standby mode.) When using a folder that has no label attachment device, this operation will not occur. 7. Press the STEP button O. Each time this button is pressed, the folder will conduct one step. Observe the tucking blade action this while. 8. After folding, the pocket and front pieces will be carried to the machine head side. 9. The feeder will move for one stitch but nothing will be sewn. 10. On completion of the last stitch, the machine will return to the shunting position. Fast feed is possible if FAST button 0 is pressed during feed operation. Feeding will stop if TEST button is pressed to turn off the TEST lamp. If TEST button 0 is pressed again, feeding will proceed; if STEP BACK button O is pressed, feeding will reverse. Fast feed back is possible if FAST button 0 is pressed during the backward operations. Notes: If the needle has descended too much during the above checking operation, press EM (emergency stop) button 0 to release the alarm when "U51" has been displayed, and turn the machine pulley to raise the needle. After the production quantity has been displayed, press START button m to finish the remaining actions and to return to the shunting position. )K At a corner, as there is inertia influence, the needle drop position may deviate a little from the position at the time of a test. -23-