Brother International BAS-760 Instruction Manual - English - Page 53

Using, Switches

Page 53 highlights

USING THE DIP SWITCHES >K Always be sure to turn the power OFF when changing the settings of the DIP switches. The functions of the DIP switches are subject to changes without notification. 1. Functions of DIP switches on main circuit board a DIP switch 3 ON OFF I U DIP switch 1 D LI "DIP switch 2 U r 1 I 2 j • DIP switch 1 No. Functions when ON 1 Model number and program number are not checked. *2 0.2 second wait after completion of sewing. 3 *4 Operation of sewing clamp sensor is enabled. 5 6 If ON when power is ON, low machine speed is set for each needle at sewing start and end. 7 X-Y variation is displayed. 8 If ON when power is ON, machine speed is set to TEST mode. • DIP switch 2 * Normally ON; all others are normally OFF. No. Functions when ON 1 Operation of needle racking cylinder sensor is enabled. 2 2-OFF Tack speed setting: 3-OFF 2,000spm 2-OFF 3-ON 2,500spm 3 2-ON 3-OFF 2,800spm 2-ON 3-ON 3,000spm 4 X right direction feeding speed (folder machine) is reduced by 20%. 5 6 7 8 Y direction feed timing is increased for all data. • DIP switch 3: Nos. 1-8 are currently all spare. Blank DIP switches are spare. -50-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

USING
THE
DIP
SWITCHES
>K
Always
be
sure
to
turn
the
power
OFF
when
changing
the
settings
of
the
DIP
switches.
The
functions
of
the
DIP
switches
are
subject
to
changes
without
notification.
1.
Functions
of
DIP
switches
on
main
circuit
board
a
U
D
LI
••
••
U
r
2
j
DIP
switch
3
DIP
switch
1
"DIP
switch
2
ON
OFF
I
1
I
DIP
switch
1
No.
Functions
when
ON
1
Model
number
and
program
number
are
not
checked.
*2
0.2
second
wait
after
completion
of
sewing.
3
*4
Operation
of
sewing
clamp
sensor
is
enabled.
5
6
If
ON
when
power
is
ON,
low
machine
speed
is
set
for
each
needle
at
sewing
start
and
end.
7
X
-Y
variation
is
displayed.
8
If
ON
when
power
is
ON,
machine
speed
is
set
to
TEST
mode.
*
Normal
ly
ON;
all
others
are
normally
OFF.
DIP
switch
2
No.
Functions
when
ON
1
Operation
of
needle
racking
cylinder
sensor
is
enabled.
2
2
-OFF
2
-OFF
2,000spm
Tack
speed
setting:
3
-OFF
3
-ON
2
-ON
2
-ON
2,800spm
3
-OFF
3
-ON
2,500spm
3,000spm
3
4
X
right
direction
feeding
speed
(folder
machine)
is
reduced
by
20%.
5
6
7
8
Y
direction
feed
timing
is
increased
for
all
data.
Blank
DIP
switches
are
spare.
DIP
switch
3:
Nos.
1-8
are
currently
all
spare.
—50-