Brother International BAS-760 Instruction Manual - English - Page 50
Stacker, position, adjustment
View all Brother International BAS-760 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Removal of the movable knife // 0 1. Remove clamping screw 0 and then presser foot assembly @. 2. Turn the pulley and stop the needle bar at its highest position. 3. Remove clamping screws @ and then bottom-plunger 0. O. 4. Push thread trimming rod in the arrowed direction and stop where flat-head screws @ can be seen. 5. Remove flat-head screws @ and then movable knife Note 1: Remove bottom-plunger 0 and movable knife f) after removing the needle. Note 2: To reassemble, reverse the above procedures. CI Stacker position adjustment 1. Release the air. Loosen bolt 0 and adjust stacker table @ to the best position. Conduct this with cylinder @ retracted. 2. Tighten bolt O. 3. Make sure that the stacker table @ will contact cover 0 when it is pushed toward cover 0. 4. Loosen the four bolts and adjust the height of stacker table @ so that the front pieces will be in a well-balanced stack. 5. Tighten bolts®. 6. Loosen bolt O and adjust the height of presser bar O. 7. Tighten bolt O. -47-