Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 32
QSFP No: 8 Channel No:0
View all Dell Brocade 5100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
• HA failover on DCX/DCX-4S/DCX 8510 platforms while running FOS v7.0 or later firmware • Firmware upgrade from v7.0 to a later release on Brocade 300, 5100, VA-40FC, 5300, 6510 • Firmware upgrade from FOSv7.0.1 to a later release on Brocade 6505 • The QSFP information in the sfpshow output will indicate the ID field as all zeros. This is as designed. ras080:FID128:root> sfpshow 5/32 QSFP No: 8 Channel No:0 Identifier: 13 QSFP+ Connector: 12 MPO Parallel Optic Transceiver: 0000000000000000 16_Gbps id • It is recommended that for directors with more than 300 E_Ports, the switch be disabled prior to executing the "switchCfgTrunk" command (used to disable or enable trunking on the switch). • During non-disruptive firmware upgrades, E_Ports in R-RDY mode may cause some frame drops on the E-port links. • For the configure command, in FOS v6.4, or later the default value that displays for Maximum Logins per switch is different than the value that displays in FOS v6.3.x. The default value has not changed; it was displayed incorrectly in FOS v6.3.x, and is now corrected. Fabric OS v7.0.2 Release Notes v1.0 Page 32 of 99