Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 84

Closed with Code Change in Fabric OS v7.0.0c

Page 84 highlights

Closed with Code Change in Fabric OS v7.0.0c Defect ID: DEFECT000365069 Technical Severity: High Summary: ICL Ports on 8510 directors show "Mod_Val" on 1 out of 4 ports on a QSFP. Symptom: Event log indicates bad QSFP requiring reseat or replacement. Workaround: Reseating QSFP may correct the issue. Feature: 16G Hardware Function: 16G QSFP Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000365071 Technical Severity: High Summary: QSFP port status is not refreshed in WebTools port admin window. Symptom: Insertion/Removal of QSFP is not reflected in Port Admin window. Workaround: Refresh, or close and re-open Port Admin window. Feature: WebMgmt Function: Ports Admin Probability: Medium Found in Release: FOS7.0.0 Defect ID: DEFECT000365075 Technical Severity: High Summary: QSFP ICL ports are being fenced due to excessive state changes even though current high threshold value is not exceeded Symptom: QSFP ICL links are getting fenced unexpectedly. Feature: FABRIC WATCH Function: PORT FENCING Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000365794 Technical Severity: High Summary: In an IPSec configuration between FX8-24 and 7800, some circuits never come online Symptom: IPSec circuits stuck in a In-progress state. Feature: FCIP Function: FCP TCP/IP Stack Probability: Low Found in Release: FOS7.0.1 Defect ID: DEFECT000368931 Technical Severity: High Summary: Deprecate FruReplace CLI command in FOS Symptom: Use of FruReplace command in the process of performing replacement of a defective WWN card will result with a potential failed transfer leaving the replacement WWN card unusable. Feature: FOS-Infrastructure Function: Other Probability: Low Found in Release: FOS7.0.0 Service Request ID: 673189 Fabric OS v7.0.2 Release Notes v1.0 Page 84 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Closed with Code Change in Fabric OS v7.0.0c
Fabric OS v7.0.2 Release Notes v1.0
Page 84 of 99
Defect ID:
DEFECT000365069
Technical Severity:
High
Summary:
ICL Ports on 8510 directors show "Mod_Val" on 1 out of 4 ports on a QSFP.
Symptom:
Event log indicates bad QSFP requiring reseat or replacement.
Workaround:
Reseating QSFP may correct the issue.
Feature:
16G Hardware
Function:
16G QSFP
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000365071
Technical Severity:
High
Summary:
QSFP port status is not refreshed in WebTools port admin window.
Symptom:
Insertion/Removal of QSFP is not reflected in Port Admin window.
Workaround:
Refresh, or close and re-open Port Admin window.
Feature:
WebMgmt
Function:
Ports Admin
Probability:
Medium
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000365075
Technical Severity:
High
Summary:
QSFP ICL ports are being fenced due to excessive state changes even though current high
threshold value is not exceeded
Symptom:
QSFP ICL links are getting fenced unexpectedly.
Feature:
FABRIC WATCH
Function:
PORT FENCING
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000365794
Technical Severity:
High
Summary:
In an IPSec configuration between FX8-24 and 7800, some circuits never come online
Symptom:
IPSec circuits stuck in a In-progress state.
Feature:
FCIP
Function:
FCP TCP/IP Stack
Probability:
Low
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000368931
Technical Severity:
High
Summary:
Deprecate FruReplace CLI command in FOS
Symptom:
Use of FruReplace command in the process of performing replacement of a defective WWN
card will result with a potential failed transfer leaving the replacement WWN card unusable.
Feature:
FOS-Infrastructure
Function:
Other
Probability:
Low
Found in Release:
FOS7.0.0
Service Request ID:
673189