Defect ID, Technical Severity, Summary, Symptom, Workaround, Feature, Function, Probability, Found
View all Dell Brocade 5100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Open Defects in Fabric OS v7.0.1 Defect ID: DEFECT000369286 Technical Severity: Medium Summary: Inconsistency in handling of unsupported port speed configuration after replacing an FC16xx blade with an FC8-xxE blade. Symptom: After replacing an FC16-xx blade with an FC8-xxE blade, ports previously configured to fixed 10G speed will be reset to auto speed negotiation while ports previously configured to fixed 16G will be persistently disabled. Workaround: Manually correct the configured port speed and reenable the port. Feature: 16G ASIC Driver Function: General Probability: High Found in Release: FOS7.0.1 Defect ID: DEFECT000371302 Technical Severity: Medium Summary: CEE/FCoE: protocol spanning tree config is not visible after spanning tree shut/no shut Symptom: If the customer changes the path cost to custom and does a shut/no shut the configuration will have flat set as standard but rest of the config will remain as custom. Workaround: Reconfigure "port-channel path-cost custom" and then configure "port-channel path-cost standard". Feature: CEE-LAYER2 Function: STP Probability: Medium Found in Release: FOS7.0.1 Defect ID: DEFECT000373589 Technical Severity: Medium Summary: The error message for a duplicate user assigned FAPWWN will show the slot/port as -1/-1 if the port is in a different logical switch. Symptom: If the user attempts to assign a WWN that has already been assigned to a port in a different logical switch, the following message is displayed: "Error: Virtual Port WWN is already mapped (FID , Switch port -1/-1)." This does not indicate the actual physical port with the duplicate WWN assignment. Workaround: Login to the FID indicated in the error message and issue "fapwwn --show all" to identify which port has the WWN already assigned. Feature: Fabric Provisioning Function: CLI Probability: High Found in Release: FOS7.0.1 Defect ID: DEFECT000374924 Technical Severity: Medium Summary: Port Admin Dialog: FC8-32E and FC8-48E blades will list speed combo values which are not supported on these platforms. Symptom: User will see speed combo values for FC8-32E and FC8-48E blades, but these settings are not valid for these blade types. Feature: WebMgmt Function: Ports Admin Probability: High Found in Release: FOS7.0.1 Fabric OS v7.0.2 Release Notes v1.0 Page 65 of 99