Open Defects in Fabric OS v7.0.1 Defect ID: DEFECT000369286 Technical Severity: Medium Summary: Inconsistency in handling of unsupported port speed configuration after replacing an FC16xx blade with an FC8-xxE blade. Symptom: After replacing an FC16-xx blade with an FC8-xxE blade, ports previously configured to fixed 10G speed will be reset to auto speed negotiation while ports previously configured to fixed 16G will be persistently disabled. Workaround: Manually correct the configured port speed and reenable the port. Feature: 16G ASIC Driver Function: General Probability: High Found in Release: FOS7.0.1 Defect ID: DEFECT000371302 Technical Severity: Medium Summary: CEE/FCoE: protocol spanning tree config is not visible after spanning tree shut/no shut Symptom: If the customer changes the path cost to custom and does a shut/no shut the configuration will have flat set as standard but rest of the config will remain as custom. Workaround: Reconfigure "port-channel path-cost custom" and then configure "port-channel path-cost standard". Feature: CEE-LAYER2 Function: STP Probability: Medium Found in Release: FOS7.0.1 Defect ID: DEFECT000373589 Technical Severity: Medium Summary: The error message for a duplicate user assigned FAPWWN will show the slot/port as -1/-1 if the port is in a different logical switch. Symptom: If the user attempts to assign a WWN that has already been assigned to a port in a different logical switch, the following message is displayed: "Error: Virtual Port WWN is already mapped (FID , Switch port -1/-1)." This does not indicate the actual physical port with the duplicate WWN assignment. Workaround: Login to the FID indicated in the error message and issue "fapwwn --show all" to identify which port has the WWN already assigned. Feature: Fabric Provisioning Function: CLI Probability: High Found in Release: FOS7.0.1 Defect ID: DEFECT000374924 Technical Severity: Medium Summary: Port Admin Dialog: FC8-32E and FC8-48E blades will list speed combo values which are not supported on these platforms. Symptom: User will see speed combo values for FC8-32E and FC8-48E blades, but these settings are not valid for these blade types. Feature: WebMgmt Function: Ports Admin Probability: High Found in Release: FOS7.0.1 Fabric OS v7.0.2 Release Notes v1.0 Page 65 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Open Defects in Fabric OS v7.0.1
Fabric OS v7.0.2 Release Notes v1.0
Page 65 of 99
Defect ID:
DEFECT000369286
Technical Severity:
Medium
Summary:
Inconsistency in handling of unsupported port speed configuration after replacing an FC16-
xx blade with an FC8-xxE blade.
Symptom:
After replacing an FC16-xx blade with an FC8-xxE blade, ports previously configured to fixed
10G speed will be reset to auto speed negotiation while ports previously configured to fixed
16G will be persistently disabled.
Workaround:
Manually correct the configured port speed and reenable the port.
Feature:
16G ASIC Driver
Function:
General
Probability:
High
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000371302
Technical Severity:
Medium
Summary:
CEE/FCoE: protocol spanning tree config is not visible after spanning tree shut/no shut
Symptom:
If the customer changes the path cost to custom and does a shut/no shut the configuration
will have flat set as standard but rest of the config will remain as custom.
Workaround:
Reconfigure “port-channel path-cost custom” and then configure “port-channel path-cost
standard".
Feature:
CEE-LAYER2
Function:
STP
Probability:
Medium
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000373589
Technical Severity:
Medium
Summary:
The error message for a duplicate user assigned FAPWWN will show the slot/port as -1/-1 if
the port is in a different logical switch.
Symptom:
If the user attempts to assign a WWN that has already been assigned to a port in a
different logical switch, the following message is displayed:
"Error: Virtual Port WWN is already mapped (FID <xxx>, Switch port -1/-1)."
This does not indicate the actual physical port with the duplicate WWN assignment.
Workaround:
Login to the FID indicated in the error message and issue "fapwwn --show all" to identify
which port has the WWN already assigned.
Feature:
Fabric Provisioning
Function:
CLI
Probability:
High
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000374924
Technical Severity:
Medium
Summary:
Port Admin Dialog: FC8-32E and FC8-48E blades will list speed combo values which are not
supported on these platforms.
Symptom:
User will see speed combo values for FC8-32E and FC8-48E blades, but these settings are
not valid for these blade types.
Feature:
WebMgmt
Function:
Ports Admin
Probability:
High
Found in Release:
FOS7.0.1