Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 75

Defect ID, Technical Severity, Summary, Symptom, Feature, Function, Probability, Found in Release,

Page 75 highlights

Closed with Code Change Defects in Fabric OS v7.0.1 Defect ID: DEFECT000317392 Summary: systemverification failing on 7800. Symptom: systemverfication test fails Feature: Diagnostics Probability: Low Found in Release: FOS6.3.1 Where Else Fixed: FOS7.0.0 GA Technical Severity: Medium Function: Other Defect ID: DEFECT000319548 Technical Severity: Medium Summary: ceeportloopbacktest and ceeportledtest does not properly process all parameters on the Brocade 8000 Symptom: Customer cannot utilize all options of the CEE port diagnostic tests Feature: Diagnostics Function: Other Probability: High Found in Release: FOS6.4.0 Service Request ID: 451771 Where Else Fixed: FOS7.0.0 GA, FOS6.4.1 b Defect ID: DEFECT000335811 Technical Severity: Medium Summary: Brocade 5450 switches crashed when latest version of enclosure management SW was used. Symptom: Brocade 5450 platform may panic if used with newer version of MMB that uses new ISMIC block which was previously not supported. Workaround: Use initial qualified MMB version Feature: Field Escalation Function: Panic / OOM Probability: Low Found in Release: FOS6.2.0 Service Request ID: 530085 Where Else Fixed: FOS6.4.2 a Defect ID: DEFECT000336933 Technical Severity: Medium Summary: Switch sends ELP to device after the device sends FLOGI during power-up sequence Symptom: When connected to 4G switch, during a specific storage device power-up sequence, host cannot access target. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.1.2 Service Request ID: 444823 Where Else Fixed: FOS6.4.2 Fabric OS v7.0.2 Release Notes v1.0 Page 75 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Closed with Code Change Defects in Fabric OS v7.0.1
Fabric OS v7.0.2 Release Notes v1.0
Page 75 of 99
Defect ID:
DEFECT000317392
Technical Severity:
Medium
Summary:
systemverification failing on 7800.
Symptom:
systemverfication test fails
Feature:
Diagnostics
Function:
Other
Probability:
Low
Found in Release:
FOS6.3.1
Where Else Fixed:
FOS7.0.0 GA
Defect ID:
DEFECT000319548
Technical Severity:
Medium
Summary:
ceeportloopbacktest and ceeportledtest does not properly process all parameters on the
Brocade 8000
Symptom:
Customer cannot utilize all options of the CEE port diagnostic tests
Feature:
Diagnostics
Function:
Other
Probability:
High
Found in Release:
FOS6.4.0
Service Request ID:
451771
Where Else Fixed:
FOS7.0.0 GA, FOS6.4.1 b
Defect ID:
DEFECT000335811
Technical Severity:
Medium
Summary:
Brocade 5450 switches crashed when latest version of enclosure management SW was
used.
Symptom:
Brocade 5450 platform may panic if used with newer version of MMB that uses new ISMIC
block which was previously not supported.
Workaround:
Use initial qualified MMB version
Feature:
Field Escalation
Function:
Panic / OOM
Probability:
Low
Found in Release:
FOS6.2.0
Service Request ID:
530085
Where Else Fixed:
FOS6.4.2 a
Defect ID:
DEFECT000336933
Technical Severity:
Medium
Summary:
Switch sends ELP to device after the device sends FLOGI during power-up sequence
Symptom:
When connected to 4G switch, during a specific storage device power-up sequence, host
cannot access target.
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
Low
Found in Release:
FOS6.1.2
Service Request ID:
444823
Where Else Fixed:
FOS6.4.2