Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 75
Defect ID, Technical Severity, Summary, Symptom, Feature, Function, Probability, Found in Release,
View all Dell Brocade 5100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Closed with Code Change Defects in Fabric OS v7.0.1 Defect ID: DEFECT000317392 Summary: systemverification failing on 7800. Symptom: systemverfication test fails Feature: Diagnostics Probability: Low Found in Release: FOS6.3.1 Where Else Fixed: FOS7.0.0 GA Technical Severity: Medium Function: Other Defect ID: DEFECT000319548 Technical Severity: Medium Summary: ceeportloopbacktest and ceeportledtest does not properly process all parameters on the Brocade 8000 Symptom: Customer cannot utilize all options of the CEE port diagnostic tests Feature: Diagnostics Function: Other Probability: High Found in Release: FOS6.4.0 Service Request ID: 451771 Where Else Fixed: FOS7.0.0 GA, FOS6.4.1 b Defect ID: DEFECT000335811 Technical Severity: Medium Summary: Brocade 5450 switches crashed when latest version of enclosure management SW was used. Symptom: Brocade 5450 platform may panic if used with newer version of MMB that uses new ISMIC block which was previously not supported. Workaround: Use initial qualified MMB version Feature: Field Escalation Function: Panic / OOM Probability: Low Found in Release: FOS6.2.0 Service Request ID: 530085 Where Else Fixed: FOS6.4.2 a Defect ID: DEFECT000336933 Technical Severity: Medium Summary: Switch sends ELP to device after the device sends FLOGI during power-up sequence Symptom: When connected to 4G switch, during a specific storage device power-up sequence, host cannot access target. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.1.2 Service Request ID: 444823 Where Else Fixed: FOS6.4.2 Fabric OS v7.0.2 Release Notes v1.0 Page 75 of 99