Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 44

Defect ID, Technical Severity, Summary, Symptom, Workaround, Risk of Fix, Feature, Probability,

Page 44 highlights

Close with Code Change in Fabric OS v7.0.2 Defect ID: DEFECT000390650 Technical Severity: Critical Summary: Device does not register FC4 type and path unable to failover Symptom: Device is not failing over to its alternate port if that alternate port happens to be on the upper part of the FC8-64 port blade such as port indexes 868 to 884 Workaround: Use port indexes 239-254 Risk of Fix: Low Feature: FOS Software Probability: Low Function: Fabric Services Reported In Release: FOS6.4.2 Service Request ID: 712525 Defect ID: DEFECT000391046 Technical Severity: Medium Summary: portledtest, portloopbacktest etc diag command are updated. Symptom: Failure is observed when running 'portledtest -npass 10', 'portloopbacktest -lb_mode 1' test Risk of Fix: Low Feature: FOS Software Probability: High Function: Diagnostics Reported In Release: FOS7.0.1 Service Request ID: 712391 Defect ID: DEFECT000391190 Technical Severity: Medium Summary: snmpd failed to restart Symptom: SNMP no longer functioning on switch. SNMP crashed and generated a core file twice then failed to restart. Risk of Fix: Low Feature: FOS Software Probability: Low Function: SNMP Reported In Release: FOS7.0.0 Service Request ID: 714615 Defect ID: DEFECT000391201 Technical Severity: Medium Summary: New threshold options available for bottleneck Symptom: User can now set alerts for congestion or latency in addition to set for both. Risk of Fix: Low Feature: Man Pages Probability: Low Function: Edit/Correct Reported In Release: FOS7.0.1 Defect ID: DEFECT000391658 Technical Severity: Medium Summary: Multivolume tape jobs failing over 7500/FR4-18i emulation Symptom: Customer gets failures on multivolume tape drive jobs over 7500/Fr4-18i jobs Risk of Fix: Low Feature: FOS Software Probability: Low Function: FCIP Reported In Release: FOS6.4.2 Service Request ID: 701075 Defect ID: DEFECT000392322 Technical Severity: Medium Summary: Emulation should free the previously aborted exchange if the Host re-uses the oxid within R_A_TOV of the BA_ACC. Symptom: FCIP Emulation not releasing aborted exchanges, potentially causing generated SCSI Busy status sequences if the exchange is reused within 22 seconds. Workaround: Disable emulation Risk of Fix: Low Feature: FCIP Probability: Medium Function: Emulation Reported In Release: FOS7.0.1 Fabric OS v7.0.2 Release Notes v1.0 Page 44 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0
Page 44 of 99
Defect ID:
DEFECT000390650
Technical Severity:
Critical
Summary:
Device does not register FC4 type and path unable to failover
Symptom:
Device
is not failing over to its alternate port if that alternate port happens to be on the upper part of
the FC8-64 port blade such as port indexes 868 to 884
Workaround:
Use port indexes 239-254
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.4.2
Service Request ID:
712525
Defect ID:
DEFECT000391046
Technical Severity:
Medium
Summary:
portledtest, portloopbacktest etc diag command are updated.
Symptom:
Failure is observed when running
'portledtest -npass 10', 'portloopbacktest -lb_mode 1' test
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
Diagnostics
Reported In Release:
FOS7.0.1
Service Request ID:
712391
Defect ID:
DEFECT000391190
Technical Severity:
Medium
Summary:
snmpd failed to restart
Symptom:
SNMP no longer functioning on switch.
SNMP crashed and generated a core file twice then failed to
restart.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
SNMP
Reported In Release:
FOS7.0.0
Service Request ID:
714615
Defect ID:
DEFECT000391201
Technical Severity:
Medium
Summary:
New threshold options available for bottleneck
Symptom:
User can now set alerts for congestion or latency in addition to set for both.
Risk of Fix:
Low
Feature:
Man Pages
Probability:
Low
Function:
Edit/Correct
Reported In Release:
FOS7.0.1
Defect ID:
DEFECT000391658
Technical Severity:
Medium
Summary:
Multivolume tape jobs failing over 7500/FR4-18i emulation
Symptom:
Customer gets failures on multivolume tape drive jobs over 7500/Fr4-18i jobs
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
FCIP
Reported In Release:
FOS6.4.2
Service Request ID:
701075
Defect ID:
DEFECT000392322
Technical Severity:
Medium
Summary:
Emulation should free the previously aborted exchange if the Host re-uses the oxid within R_A_TOV
of the BA_ACC.
Symptom:
FCIP Emulation not releasing aborted exchanges, potentially causing generated SCSI Busy status
sequences if the exchange is reused within 22 seconds.
Workaround:
Disable emulation
Risk of Fix:
Low
Feature:
FCIP
Probability:
Medium
Function:
Emulation
Reported In Release:
FOS7.0.1