Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 83

Defect ID, Technical Severity, Summary, Symptom, Feature, Function, Probability, Found in Release,

Page 83 highlights

Closed with Code Change in Fabric OS v7.0.0c - GA November 18, 2011 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of November 18, 2011 in Fabric OS v7.0.0c Defect ID: DEFECT000354348 Technical Severity: High Summary: Not receiving the RAS log Cx-5021 message for front port partial credit loss on an EX-Port Symptom: Customer will be unaware if EX_Ports are leaking credit. Feature: 8G FCR Function: FCR Daemon Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000364137 Technical Severity: High Summary: FabricWatch Port Class is not monitoring ICL ports. E-Port Class monitors are monitoring ICL ports. Symptom: ICL Ports will not report any threshold warnings and will not be fenced for Port Class attributes. Feature: FABRIC WATCH Function: PORT FENCING Probability: High Found in Release: FOS7.0.0 Defect ID: DEFECT000364799 Technical Severity: High Summary: After downgrading from v7.0.0 to v6.4.x, a route rebalance or recalculation will cause some ICL paths to be blocked. Symptom: Connectivity between devices lost after route change. Workaround: Disable all ICL ports and then enable all ICL ports. Feature: UNDETERMINED Function: UNDER REVIEW Probability: High Found in Release: FOS6.4.2 Defect ID: DEFECT000364945 Technical Severity: High Summary: Unable create 4th tunnel with crossport circuits in chassis with multiple FX8-24 blades. Symptom: Unable create more than three tunnels with crossport circuit configuration in a chassis with multiple FX8-24 blades. Feature: FCIP Function: Other Probability: High Found in Release: FOS7.0.0 Fabric OS v7.0.1b Release Notes v1.0 Page 83 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Fabric OS v7.0.1b Release Notes v1.0
Page 83 of 99
Closed with Code Change in Fabric OS v7.0.0c – GA November 18, 2011
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
November 18, 2011 in Fabric OS v7.0.0c
Defect ID:
DEFECT000354348
Technical Severity:
High
Summary:
Not receiving the RAS log
Cx-5021 message for front port partial credit loss on an EX-Port
Symptom:
Customer will be unaware if EX_Ports are leaking credit.
Feature:
8G FCR
Function:
FCR Daemon
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000364137
Technical Severity:
High
Summary:
FabricWatch Port Class is not monitoring ICL ports.
E-Port Class monitors are monitoring
ICL ports.
Symptom:
ICL Ports will not report any threshold warnings and will not be fenced for Port Class
attributes.
Feature:
FABRIC WATCH
Function:
PORT FENCING
Probability:
High
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000364799
Technical Severity:
High
Summary:
After downgrading from v7.0.0 to v6.4.x, a route rebalance or recalculation will cause some
ICL paths to be blocked.
Symptom:
Connectivity between devices lost after route change.
Workaround:
Disable all ICL ports and then enable all ICL ports.
Feature:
UNDETERMINED
Function:
UNDER REVIEW
Probability:
High
Found in Release:
FOS6.4.2
Defect ID:
DEFECT000364945
Technical Severity:
High
Summary:
Unable create 4th tunnel with crossport circuits in chassis with multiple FX8-24 blades.
Symptom:
Unable create more than three tunnels with crossport circuit configuration in a chassis with
multiple FX8-24 blades.
Feature:
FCIP
Function:
Other
Probability:
High
Found in Release:
FOS7.0.0