Close with Code Change in Fabric OS v7.0.2 Defect ID: DEFECT000379996 Technical Severity: High Summary: Configdownload fails with segmentation fault. Symptom: If a configdownload is done to a chassis having motd set with a config file having no motd set, confidownload operation will fail due to 'segmentation fault' Risk of Fix: Low Feature: FOS Security Probability: Low Function: Other Reported In Release: FOS7.0.1 Defect ID: DEFECT000380162 Technical Severity: Medium Summary: F-Port trunk lost connectivity after hafailover Symptom: When a hafailover occurs on a fabric switch with F-port trunks, the fabric ID is not updated on the slave ports of the F-port trunks. This causes the slave ports to have a possibly incorrect fabric ID. If the entire F-port trunk goes down and a previous slave port becomes the trunk master of the F-port trunk, this incorrect fabric ID is used and cause ACL check to fail and frame cannot go through. Risk of Fix: Low Feature: FOS Software Probability: Low Function: Access Gateway Reported In Release: FOS6.4.2 Service Request ID: 691443 Defect ID: DEFECT000381210 Technical Severity: High Summary: Disk Controller warm start processing causing multiple IFCCs Symptom: Multiple IFCCs occur after warm start processing completed on a FICON Disk Controller. The number of IFCCs can cause XRC suspends. Risk of Fix: Low Feature: FCIP Probability: Medium Function: Emulation Reported In Release: FOS7.0.0 Defect ID: DEFECT000381270 Technical Severity: Medium Summary: switch panic during SFP validation Symptom: While running diagnostics, an unsuccessful read at low level or bad SFP/media itself can trigger switch panic Risk of Fix: Low Feature: FOS Software Probability: Low Function: Diagnostics Reported In Release: FOS6.3.1 Service Request ID: 499697 Defect ID: DEFECT000381305 Technical Severity: High Summary: Fabric Watch messages reporting TX/RX values above 100% Symptom: Fabric Watch messages reporting TX and RX performance values above 100%: 2011/12/06-19:29:58, [FW-1190], 1425, SLOT 6 | FID 128, INFO, FOP Port#3/30,TX Performance, is above high boundary(High=85, Low=0). Current value is 137 Percentage(%)/minute. Risk of Fix: Low Feature: FOS Software Probability: Low Function: Management Services Reported In Release: FOS6.3.2 Service Request ID: 693491,683501 Fabric OS v7.0.2 Release Notes v1.0 Page 37 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0
Page 37 of 99
Defect ID:
DEFECT000379996
Technical Severity:
High
Summary:
Configdownload fails with segmentation fault.
Symptom:
If a configdownload is done to
a chassis having motd set with a config file having no motd set,
confidownload operation will fail due to ‘segmentation fault’
Risk of Fix:
Low
Feature:
FOS Security
Probability:
Low
Function:
Other
Reported In Release:
FOS7.0.1
Defect ID:
DEFECT000380162
Technical Severity:
Medium
Summary:
F-Port trunk lost connectivity after hafailover
Symptom:
When a hafailover occurs on a fabric switch with F-port trunks, the fabric ID is not updated on the
slave ports of the F-port trunks.
This causes the slave ports to have a possibly incorrect fabric ID.
If
the entire F-port trunk goes down and a previous slave port becomes the trunk master of the F-port
trunk, this incorrect fabric ID is used and cause ACL check to fail and frame cannot go through.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Access Gateway
Reported In Release:
FOS6.4.2
Service Request ID:
691443
Defect ID:
DEFECT000381210
Technical Severity:
High
Summary:
Disk Controller warm start processing causing multiple IFCCs
Symptom:
Multiple IFCCs occur after warm start processing completed on a FICON Disk Controller.
The
number of IFCCs can cause XRC suspends.
Risk of Fix:
Low
Feature:
FCIP
Probability:
Medium
Function:
Emulation
Reported In Release:
FOS7.0.0
Defect ID:
DEFECT000381270
Technical Severity:
Medium
Summary:
switch panic during SFP validation
Symptom:
While running diagnostics, an unsuccessful read at low level or bad SFP/media itself can trigger
switch panic
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Diagnostics
Reported In Release:
FOS6.3.1
Service Request ID:
499697
Defect ID:
DEFECT000381305
Technical Severity:
High
Summary:
Fabric Watch messages reporting TX/RX values above 100%
Symptom:
Fabric Watch messages reporting TX and RX performance values above 100%:
2011/12/06-19:29:58, [FW-1190], 1425, SLOT 6 | FID 128, INFO, FOP Port#3/30,TX Performance,
is above high boundary(High=85, Low=0). Current value is 137 Percentage(%)/minute.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Management Services
Reported In Release:
FOS6.3.2
Service Request ID: