Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 54
Defect ID, Technical Severity, Summary, Symptom, Feature, Function, Probability, Found in Release,
View all Dell Brocade 5100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
Close with Code Change in Fabric OS v7.0.2 Defect ID: DEFECT000386010 Technical Severity: Medium Summary: Device does re-FLOGI with a different WWN cause stale entry in Flogin DataBase Symptom: switch reports duplicate WWN and panic. Feature: Field Escalation Function: Panic / OOM Probability: Medium Found in Release: FOS6.4.2 Service Request ID: 700637,722117 Where Else Fixed: FOS6.4.3 Defect ID: DEFECT000386559 Technical Severity: Medium Summary: Good EOF CRC errors Symptom: Customer is seeing C2-1006 and C2-1010 messages reporting internal link errors without hardware fault. The issue are associated with Good EOF CRC errors: This defect tracks SERDES tuning for FS8-18 in DCX on slot 12, FC8-16 on DCX4s in slot1,2,7... Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.1 Service Request ID: 704947 Where Else Fixed: FOS6.4.3 Defect ID: DEFECT000387601 Technical Severity: Medium Summary: Embedded platform with internal CU port turned into G Port Symptom: This server lost access to the devices when internal CU port connected to HBA turned into G_Port. Feature: 8G ASIC Driver Function: ASIC Driver Probability: Medium Found in Release: FOS7.0.1 Defect ID: DEFECT000389731 Technical Severity: Medium Summary: FICON Emulation is not handling IU pacing updates properly Symptom: Customer would see aborts on the fabric, and the customer reports that they went down because they were not getting frames fast enough from the 7500's. Feature: Field Escalation Function: FICON Probability: Medium Found in Release: FOS6.4.2 Service Request ID: 684047 FOS6.4.3, Defect ID: DEFECT000391046 Technical Severity: Medium Summary: portledtest, portloopbacktest etc diag command are updated. Symptom: Failure is observed when running 'portledtest -npass 10', 'portloopbacktest -lb_mode 1' test Workaround: No Feature: Field Escalation Function: Diagnostics Probability: High Found in Release: FOS7.0.1 Service Request ID: 712391 Fabric OS v7.0.2 Release Notes v1.0 Page 54 of 99