Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 54

Defect ID, Technical Severity, Summary, Symptom, Feature, Function, Probability, Found in Release,

Page 54 highlights

Close with Code Change in Fabric OS v7.0.2 Defect ID: DEFECT000386010 Technical Severity: Medium Summary: Device does re-FLOGI with a different WWN cause stale entry in Flogin DataBase Symptom: switch reports duplicate WWN and panic. Feature: Field Escalation Function: Panic / OOM Probability: Medium Found in Release: FOS6.4.2 Service Request ID: 700637,722117 Where Else Fixed: FOS6.4.3 Defect ID: DEFECT000386559 Technical Severity: Medium Summary: Good EOF CRC errors Symptom: Customer is seeing C2-1006 and C2-1010 messages reporting internal link errors without hardware fault. The issue are associated with Good EOF CRC errors: This defect tracks SERDES tuning for FS8-18 in DCX on slot 12, FC8-16 on DCX4s in slot1,2,7... Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.1 Service Request ID: 704947 Where Else Fixed: FOS6.4.3 Defect ID: DEFECT000387601 Technical Severity: Medium Summary: Embedded platform with internal CU port turned into G Port Symptom: This server lost access to the devices when internal CU port connected to HBA turned into G_Port. Feature: 8G ASIC Driver Function: ASIC Driver Probability: Medium Found in Release: FOS7.0.1 Defect ID: DEFECT000389731 Technical Severity: Medium Summary: FICON Emulation is not handling IU pacing updates properly Symptom: Customer would see aborts on the fabric, and the customer reports that they went down because they were not getting frames fast enough from the 7500's. Feature: Field Escalation Function: FICON Probability: Medium Found in Release: FOS6.4.2 Service Request ID: 684047 FOS6.4.3, Defect ID: DEFECT000391046 Technical Severity: Medium Summary: portledtest, portloopbacktest etc diag command are updated. Symptom: Failure is observed when running 'portledtest -npass 10', 'portloopbacktest -lb_mode 1' test Workaround: No Feature: Field Escalation Function: Diagnostics Probability: High Found in Release: FOS7.0.1 Service Request ID: 712391 Fabric OS v7.0.2 Release Notes v1.0 Page 54 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0
Page 54 of 99
Defect ID:
DEFECT000386010
Technical Severity:
Medium
Summary:
Device does re-FLOGI with a different WWN cause stale entry in Flogin DataBase
Symptom:
switch reports duplicate WWN and panic.
Feature:
Field Escalation
Function:
Panic / OOM
Probability:
Medium
Found in Release:
FOS6.4.2
Service Request ID:
700637,722117
Where Else Fixed:
FOS6.4.3
Defect ID:
DEFECT000386559
Technical Severity:
Medium
Summary:
Good EOF CRC errors
Symptom:
Customer is seeing C2-1006 and C2-1010 messages reporting internal link errors without
hardware fault. The issue are associated with Good EOF CRC errors:
This defect tracks
SERDES tuning for FS8-18 in DCX on slot 12,
FC8-16 on DCX4s in slot1,2,7...
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
Low
Found in Release:
FOS6.4.1
Service Request ID:
704947
Where Else Fixed:
FOS6.4.3
Defect ID:
DEFECT000387601
Technical Severity:
Medium
Summary:
Embedded platform with internal CU port turned into G Port
Symptom:
This server lost access to the devices when internal CU port connected to HBA turned into
G_Port.
Feature:
8G ASIC Driver
Function:
ASIC Driver
Probability:
Medium
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000389731
Technical Severity:
Medium
Summary:
FICON Emulation is not handling IU pacing updates properly
Symptom:
Customer would see aborts on the fabric, and the customer reports that they went down
because they were not getting frames fast enough from the 7500's.
Feature:
Field Escalation
Function:
FICON
Probability:
Medium
Found in Release:
FOS6.4.2
Service Request ID:
684047
FOS6.4.3,
Defect ID:
DEFECT000391046
Technical Severity:
Medium
Summary:
portledtest, portloopbacktest etc diag command are updated.
Symptom:
Failure is observed when running
'portledtest -npass 10', 'portloopbacktest -lb_mode 1'
test
Workaround:
No
Feature:
Field Escalation
Function:
Diagnostics
Probability:
High
Found in Release:
FOS7.0.1
Service Request ID:
712391