Closed with Code Change in Fabric OS v7.0.0b Defect ID: DEFECT000354560 Technical Severity: Medium Summary: Failed tape jobs encountered with tape pipelining enabled when utilizing a FICON to ESCON converter Symptom: Tape jobs intermittently fail with tape pipelining enabled when utilizing a FICON to ESCON converter. Workaround: Disable tape pipelining Feature: Field Escalation Function: FCIP Probability: Medium Found in Release: FOS6.4.2 Where Else Fixed: FOS6.4.2 a Defect ID: DEFECT000354750 Technical Severity: Medium Summary: Unable to access the boot prom on a 5480 when it is installed in a C-7000 chassis Symptom: Unable to access the boot prom on a 5480. Feature: UNDETERMINED Function: UNDER REVIEW Probability: Low Found in Release: FOS6.3.1 Service Request ID: 589577 Defect ID: DEFECT000354967 Technical Severity: Medium Summary: WebTools: When attempting to upgrade a switch in IM2/IM3 to FOS v7.0, fail message should direct user to Interoperability tab to change switch to Brocade Native Fabric Mode Symptom: When upgrading a switch in IM2/IM3 to v7.0 via WebTools, the failure message references the interopmode command, but does not provide WebTools instructions. Feature: FC Services Function: Other Probability: Medium Found in Release: FOS7.0.0 Defect ID: DEFECT000355888 Technical Severity: Medium Summary: D_Port (CLI): Caution message should not mention Brocade Branded SFPs. Symptom: Caution message seen when executing D_Port CLI mentions "only Brocade Branded SFPs". Feature: FC Services Function: D-port Probability: High Found in Release: FOS7.0.0 Defect ID: DEFECT000355909 Technical Severity: Medium Summary: perfaddusermonitor/fmconfig not correctly counting SOFf frames Symptom: SOFf frame counter is not detecting SOFf frame ingress/egress when filter monitor is enabled. Feature: Field Escalation Function: ASIC Driver Probability: High Found in Release: FOS6.4.2 Service Request ID: 632819 Fabric OS v7.0.2 Release Notes v1.0 Page 91 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Closed with Code Change in Fabric OS v7.0.0b
Fabric OS v7.0.2 Release Notes v1.0
Page 91 of 99
Defect ID:
DEFECT000354560
Technical Severity:
Medium
Summary:
Failed tape jobs encountered with tape pipelining enabled when utilizing a FICON to ESCON
converter
Symptom:
Tape jobs intermittently fail with tape pipelining enabled when utilizing a FICON to ESCON
converter.
Workaround:
Disable tape pipelining
Feature:
Field Escalation
Function:
FCIP
Probability:
Medium
Found in Release:
FOS6.4.2
Where Else Fixed:
FOS6.4.2 a
Defect ID:
DEFECT000354750
Technical Severity:
Medium
Summary:
Unable to access the boot prom on a 5480 when it is installed in a C-7000 chassis
Symptom:
Unable to access the boot prom on a 5480.
Feature:
UNDETERMINED
Function:
UNDER REVIEW
Probability:
Low
Found in Release:
FOS6.3.1
Service Request ID:
589577
Defect ID:
DEFECT000354967
Technical Severity:
Medium
Summary:
WebTools: When attempting to upgrade a switch in IM2/IM3 to FOS v7.0, fail message
should direct user to Interoperability tab to change switch to Brocade Native Fabric Mode
Symptom:
When upgrading a switch in IM2/IM3 to v7.0 via WebTools, the failure message references
the interopmode command, but does not provide WebTools instructions.
Feature:
FC Services
Function:
Other
Probability:
Medium
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000355888
Technical Severity:
Medium
Summary:
D_Port (CLI):
Caution message should not mention Brocade Branded SFPs.
Symptom:
Caution message seen when executing D_Port CLI mentions "only Brocade Branded SFPs".
Feature:
FC Services
Function:
D-port
Probability:
High
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000355909
Technical Severity:
Medium
Summary:
perfaddusermonitor/fmconfig not correctly counting SOFf frames
Symptom:
SOFf frame counter is not detecting SOFf frame ingress/egress when filter monitor is
enabled.
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
High
Found in Release:
FOS6.4.2
Service Request ID:
632819