Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 87

Closed with Code Change in Fabric OS v7.0.0b

Page 87 highlights

Closed with Code Change in Fabric OS v7.0.0b Defect ID: DEFECT000352764 Technical Severity: High Summary: Remote data replication application fails with multiple paths (multiple port pairs between arrays) when FastWrite is enabled on the FCIP tunnel. Symptom: With FastWrite enabled on an FCIP tunnel, and two data replication port pairs, the application commands to move data between the arrays will fail. With only a single port pair or with FastWrite disabled, everything works fine. Feature: FCIP Function: Emulation Probability: High Found in Release: FOS7.0.0 Defect ID: DEFECT000353981 Technical Severity: High Summary: D-Port failures seen in stress and corner case scenarios. Symptom: D-port test stays "in progress" for a long period of time and eventually times out. Workaround: portdporttest --stop and disable/enable the port Feature: FC Services Function: D-port Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000354980 Technical Severity: High Summary: FIPS: Firmwaredownload signature verification fails for directors Symptom: During a firmwaredownload, invalid packages might not be detected by directors. This could lead to invalid packages being loaded as valid firmware. Feature: FOS-Infrastructure Function: Firmware Download Probability: Medium Found in Release: FOS7.0.0 Defect ID: DEFECT000355613 Technical Severity: High Summary: Fabricd crash encountered during D-port testing Symptom: Fabricd crash could be encountered when utilizing D_Port functionality Feature: FC Services Function: D-port Probability: Medium Found in Release: FOS7.0.0 Defect ID: DEFECT000355830 Technical Severity: High Summary: Fabric Watch and Port Fencing Threshold settings should not apply to D-Ports. Symptom: D-Ports become fenced during d-port testing. Feature: FABRIC WATCH Function: PORT FENCING Probability: Medium Found in Release: FOS7.0.0 Fabric OS v7.0.2 Release Notes v1.0 Page 87 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Closed with Code Change in Fabric OS v7.0.0b
Fabric OS v7.0.2 Release Notes v1.0
Page 87 of 99
Defect ID:
DEFECT000352764
Technical Severity:
High
Summary:
Remote data replication application fails with multiple paths (multiple port pairs between
arrays) when FastWrite is enabled on the FCIP tunnel.
Symptom:
With FastWrite enabled on an FCIP tunnel, and two data replication port pairs, the
application commands to move data between the arrays will fail.
With only a single port
pair or with FastWrite disabled, everything works fine.
Feature:
FCIP
Function:
Emulation
Probability:
High
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000353981
Technical Severity:
High
Summary:
D-Port failures seen in stress and corner case scenarios.
Symptom:
D-port test stays "in progress" for a long period of time and eventually times out.
Workaround:
portdporttest --stop and disable/enable the port
Feature:
FC Services
Function:
D-port
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000354980
Technical Severity:
High
Summary:
FIPS: Firmwaredownload signature verification fails for directors
Symptom:
During a firmwaredownload, invalid packages might not be detected by directors. This
could lead to invalid packages being loaded as valid firmware.
Feature:
FOS-Infrastructure
Function:
Firmware Download
Probability:
Medium
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000355613
Technical Severity:
High
Summary:
Fabricd crash encountered during D-port testing
Symptom:
Fabricd crash could be encountered when utilizing D_Port functionality
Feature:
FC Services
Function:
D-port
Probability:
Medium
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000355830
Technical Severity:
High
Summary:
Fabric Watch and Port Fencing Threshold settings should not apply to D-Ports.
Symptom:
D-Ports become fenced during d-port testing.
Feature:
FABRIC WATCH
Function:
PORT FENCING
Probability:
Medium
Found in Release:
FOS7.0.0