Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 33

Defects

Page 33 highlights

Close with Code Change in Fabric OS v7.0.2 Defects Closed with Code Change in Fabric OS v7.0.2 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of May 15, 2012 in Fabric OS v7.0.1b. Defect ID: DEFECT000285745 Technical Severity: High Summary: Kernel watchdog timer expired when pulling Ethernet cable or connected to an unstable link Symptom: Switch kernel watchdog panics with BR5100 and BR5300 occasionally Risk of Fix: Low Feature: OS Services Probability: Low Function: Linux Kernal Reported In Release: FOS6.2.0 Service Request ID: 423329 Defect ID: DEFECT000314056 Technical Severity: Medium Summary: Due to incorrect internal counter logic, PORT-1003 port faults are being reported in the RASLOG when they shouldn't be. Symptom: After a long switch uptime, if there are greater than 50 link down events before a switch is rebooted (as opposed to within 2 minutes), the port is faulted with a PORT-1003 being reported in the RASLOG. Risk of Fix: Low Feature: Diagnostics Probability: Low Function: Other Reported In Release: FOS5.3.0 Service Request ID: 443043 Defect ID: DEFECT000334584 Technical Severity: Medium Summary: FDISC ACC is not being properly translated on AG Symptom: When booting up 3rd party virtualization platform connected to an AG, devices do not communicate properly. This problem is unlikely and is only seen when a device does FDISC followed by FLOGO for the same device PWWN. Risk of Fix: High Feature: FOS Software Probability: Low Function: Access Gateway Reported In Release: FOS6.2.2 Service Request ID: 519669 Defect ID: DEFECT000347173 Technical Severity: Medium Summary: HAfailover on the Brocade 48000 with FC8-xx blades installed may encounter rare race condition Symptom: If this rare condition is encountered, a reset of the port blades may result causing temporary traffic disruption Risk of Fix: Low Feature: FOS Software Probability: Low Function: Panic / OOM Reported In Release: FOS6.1.2 Service Request ID: 595467 Defect ID: DEFECT000353341 Technical Severity: High Summary: When XISL is disabled in VF, it leaves a condition that can trigger route problem. Symptom: Connectivity is lost across VF with a large numbers of c3_other_discards. Risk of Fix: Low Feature: FOS Software Probability: Low Function: FC Layer 2 Routing Reported In Release: FOS6.3.1 Service Request ID: 626039 690279

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Close with Code Change in Fabric OS v7.0.2
Defects
Closed with Code Change in Fabric OS v7.0.2
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
May 15, 2012 in Fabric OS v7.0.1b.
Defect ID:
DEFECT000285745
Technical Severity:
High
Summary:
Kernel watchdog timer expired when pulling Ethernet cable or connected to an unstable link
Symptom:
Switch kernel watchdog panics
with BR5100
and BR5300 occasionally
Risk of Fix:
Low
Feature:
OS Services
Probability:
Low
Function:
Linux Kernal
Reported In Release:
FOS6.2.0
Service Request ID:
423329
Defect ID:
DEFECT000314056
Technical Severity:
Medium
Summary:
Due to incorrect internal counter logic, PORT-1003 port faults are being reported in the RASLOG
when they shouldn't be.
Symptom:
After a long switch uptime, if there are
greater than 50 link down events before a switch is rebooted
(as opposed to within 2 minutes),
the port is faulted with a PORT-1003 being reported in the
RASLOG.
Risk of Fix:
Low
Feature:
Diagnostics
Probability:
Low
Function:
Other
Reported In Release:
FOS5.3.0
Service Request ID:
443043
Defect ID:
DEFECT000334584
Technical Severity:
Medium
Summary:
FDISC ACC is not being properly translated on AG
Symptom:
When booting up 3rd party virtualization platform connected to an AG,
devices do not communicate
properly. This problem is unlikely and is only seen when a device does FDISC followed by FLOGO
for the same device PWWN.
Risk of Fix:
High
Feature:
FOS Software
Probability:
Low
Function:
Access Gateway
Reported In Release:
FOS6.2.2
Service Request ID:
519669
Defect ID:
DEFECT000347173
Technical Severity:
Medium
Summary:
HAfailover on the Brocade 48000 with FC8-xx blades installed may encounter rare race condition
Symptom:
If this rare condition is encountered, a reset of the port blades may result causing temporary traffic
disruption
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Panic / OOM
Reported In Release:
FOS6.1.2
Service Request ID:
595467
Defect ID:
DEFECT000353341
Technical Severity:
High
Summary:
When XISL is disabled in VF, it leaves a condition that can trigger route problem.
Symptom:
Connectivity is lost across VF with a large numbers of c3_other_discards.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
FC Layer 2 Routing
Reported In Release:
FOS6.3.1
Service Request ID:
626039 690279