Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 64

Open Defects in Fabric OS v7.0.1

Page 64 highlights

Open Defects in Fabric OS v7.0.1 Defect ID: DEFECT000342944 Technical Severity: Medium Summary: WebTools dialog does not include FID in the error message resulting from Config Download failure on DCX with multiple logical switches. Symptom: If configdownload fails for a particular fid while being performed through WebTools , the displayed error message does not include the logical switch FID. Feature: FOS-Infrastructure Function: Config Download Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000348045 Technical Severity: Medium Summary: Fabric Watch is not properly triggering E-Port state change events. Symptom: Fabric Watch logs will not include E-Port state changes events. Workaround: Use Fabric Watch Port Class to monitor state changes. Feature: Field Escalation Function: Fabric Services Probability: Medium Found in Release: FOS6.3.2 Service Request ID: SR 586189 Defect ID: DEFECT000367062 Technical Severity: Medium Summary: Manually stopping D-Port tests may result in software verify error. Symptom: User sees the following software verify error message after manually stopping D-Port tests. "VERIFY - Failed expression: (SM_SUCCESS == dp_return)" Workaround: Workaround is to leave D-Port tests running to completion and not stop them. Feature: FC Services Function: D-port Probability: Medium Found in Release: FOS7.0.1 Defect ID: DEFECT000367436 Technical Severity: Medium Summary: Fabric Watch email alerts use the default switch name instead of current switch name in the "Sent From" field. Symptom: The 'sent from' field name in a Fabric watch email alert is the default switch name instead of current switch name for the FID. Feature: FABRIC WATCH Function: Other Probability: High Found in Release: FOS7.0.1 Defect ID: DEFECT000367477 Technical Severity: Medium Summary: SSH "Allowed User" usernames are converted to all lower case when saved to the configuration file. Symptom: Sshutil command will fail for the usernames containing upper case letters. Workaround: Run sshutil command with username converted to all lower case letters, or avoid configuring usernames with upper case letters. Feature: FOS Security Function: SSH Probability: Medium Found in Release: FOS7.0.1 Fabric OS v7.0.2 Release Notes v1.0 Page 64 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Open Defects in Fabric OS v7.0.1
Fabric OS v7.0.2 Release Notes v1.0
Page 64 of 99
Defect ID:
DEFECT000342944
Technical Severity:
Medium
Summary:
WebTools dialog does not include FID in the error message resulting from Config Download
failure on DCX with multiple logical switches.
Symptom:
If configdownload fails for a particular fid while being performed through WebTools , the
displayed error message does not include the logical switch FID.
Feature:
FOS-Infrastructure
Function:
Config Download
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000348045
Technical Severity:
Medium
Summary:
Fabric Watch is not properly triggering E-Port state change events.
Symptom:
Fabric Watch logs will not include E-Port state changes events.
Workaround:
Use Fabric Watch Port Class to monitor state changes.
Feature:
Field Escalation
Function:
Fabric Services
Probability:
Medium
Found in Release:
FOS6.3.2
Service Request ID:
SR 586189
Defect ID:
DEFECT000367062
Technical Severity:
Medium
Summary:
Manually stopping D-Port tests may result in software verify error.
Symptom:
User sees the following software verify error message after manually stopping D-Port tests.
"VERIFY - Failed expression: (SM_SUCCESS == dp_return)"
Workaround:
Workaround is to leave D-Port tests running to completion and not stop them.
Feature:
FC Services
Function:
D-port
Probability:
Medium
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000367436
Technical Severity:
Medium
Summary:
Fabric Watch email alerts use the default switch name instead of current switch name in
the "Sent From" field.
Symptom:
The 'sent from' field name in a Fabric watch email alert is the default switch name instead
of current switch name for the FID.
Feature:
FABRIC WATCH
Function:
Other
Probability:
High
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000367477
Technical Severity:
Medium
Summary:
SSH "Allowed User" usernames are converted to all lower case when saved to the
configuration file.
Symptom:
Sshutil command will fail for the usernames containing upper case letters.
Workaround:
Run sshutil command with username converted to all lower case letters, or avoid
configuring usernames with upper case letters.
Feature:
FOS Security
Function:
SSH
Probability:
Medium
Found in Release:
FOS7.0.1