Close with Code Change in Fabric OS v7.0.2 Defect ID: DEFECT000387371 Technical Severity: Medium Summary: Replication application getting errors after upgrading from FOSv6.4.1_fcoe to FOSv7.0.x with FCIP emulation Symptom: Customer will get failures in Teradata replication Risk of Fix: Low Feature: FOS Software Probability: High Function: FCIP Reported In Release: FOS7.0.0 Service Request ID: 706489 Defect ID: DEFECT000387536 Technical Severity: Medium Summary: Perfttmon only seems to output ingress values when egress is chosen Symptom: In NPIV setup, unable to get valid data for running perfttmon. Risk of Fix: Low Feature: FOS Software Probability: High Function: ASIC Driver Reported In Release: FOS7.0.1 Service Request ID: 693225 Defect ID: DEFECT000387601 Technical Severity: Medium Summary: Embedded platform with internal CU port turned into G Port Symptom: Server lost access to the devices when internal CU port connected to HBA turned into G_Port. Risk of Fix: Medium Feature: 8G ASIC Driver Probability: Medium Function: ASIC Driver Reported In Release: FOS7.0.1 Defect ID: DEFECT000388283 Technical Severity: Medium Summary: zoned caused switch panic Symptom: During rename zone, add new zone name in list and then remove the old zone name, switch panic. Risk of Fix: Low Feature: FOS Software Probability: Low Function: Fabric Services Reported In Release: FOS6.3.2 Defect ID: DEFECT000388672 Technical Severity: Medium Summary: FCIP tunnel bounces on 7800, high emulated IO can cause local keep alive timeout Symptom: Customer will get FICON keep alive timeout if there is not enough bandwidth on the FCIP tunnel. Risk of Fix: Medium Feature: FOS Software Probability: Low Function: FCIP Reported In Release: FOS6.4.1 Service Request ID: 670797 Defect ID: DEFECT000388762 Technical Severity: High Summary: Switch upgrade from FOS 6.3.x to 6.4.x in IM2/IM3 mode caused zone daemon memory space over run. Symptom: Zoned panic after upgrade, when a remote domain goes out of fabric. Workaround: To avoid this problem the customer can just do a hafailover when the firmware is completely upgraded. Risk of Fix: Low Feature: FOS Software Probability: Low Function: Fabric Services Reported In Release: FOS6.4.1 Service Request ID: 709913 Fabric OS v7.0.2 Release Notes v1.0 Page 42 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0
Page 42 of 99
Defect ID:
DEFECT000387371
Technical Severity:
Medium
Summary:
Replication application getting errors after upgrading from FOSv6.4.1_fcoe to FOSv7.0.x with FCIP
emulation
Symptom:
Customer will get failures in Teradata replication
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
FCIP
Reported In Release:
FOS7.0.0
Service Request ID:
706489
Defect ID:
DEFECT000387536
Technical Severity:
Medium
Summary:
Perfttmon only seems to output ingress values when egress is chosen
Symptom:
In NPIV setup, unable to get valid data for running perfttmon.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
ASIC Driver
Reported In Release:
FOS7.0.1
Service Request ID:
693225
Defect ID:
DEFECT000387601
Technical Severity:
Medium
Summary:
Embedded platform with internal CU port turned into G Port
Symptom:
Server lost access to the devices when internal CU port connected to HBA turned into G_Port.
Risk of Fix:
Medium
Feature:
8G ASIC Driver
Probability:
Medium
Function:
ASIC Driver
Reported In Release:
FOS7.0.1
Defect ID:
DEFECT000388283
Technical Severity:
Medium
Summary:
zoned caused switch panic
Symptom:
During rename zone, add new zone name in list and then remove the old zone name, switch panic.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.3.2
Defect ID:
DEFECT000388672
Technical Severity:
Medium
Summary:
FCIP tunnel bounces on 7800, high emulated IO can cause local keep alive timeout
Symptom:
Customer will get FICON keep alive timeout if there is not enough bandwidth on the FCIP tunnel.
Risk of Fix:
Medium
Feature:
FOS Software
Probability:
Low
Function:
FCIP
Reported In Release:
FOS6.4.1
Service Request ID:
670797
Defect ID:
DEFECT000388762
Technical Severity:
High
Summary:
Switch upgrade from FOS 6.3.x to 6.4.x in IM2/IM3 mode caused zone daemon memory space over
run.
Symptom:
Zoned panic after upgrade, when a remote domain goes out of fabric.
Workaround:
To avoid this problem the customer can just do a hafailover when the firmware is
completely upgraded.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.4.1
Service Request ID:
709913