Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 95

Closed with Code Change in Fabric OS v7.0.0a - GA June 2, 2011

Page 95 highlights

Closed with Code Change in Fabric OS v7.0.0a - GA June 2, 2011 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of June 2, 2011 in Fabric OS v7.0.0a. Defect ID: DEFECT000321855 Technical Severity: High Summary: CRC and/or CDR-5021 errors seen on DCX, DCX-4S, or 5100 switch platforms Symptom: CRC or other errors as described below: 1. Port 7/0 detected CRC error with good EOF when FC8-16 is placed in DCX-4s Slot7. For the solution to be effective, one must execute: serdestunemode --set; 2. Port 7/0, 7/10 detected CRC error when FX8-24 is placed in DCX4s slot7. May also see CRC error on corresponding core blade backend port 3/10 6/30. Solution is effective upon upgrade, hafailover or re-init of blade. 3. 5100 experience CRC error with 3rd party tape device. 4. FC10-6 in DCX detects backend port with stuck VC after link level error (CDR-5021) Feature: FC10-6 Platform Services Function: ASIC Driver Probability: Low Found in Release: FOS6.3.1 Service Request ID: 451697 Where Else Fixed: FOS7.0.0 GA Defect ID: DEFECT000345259 Technical Severity: High Summary: FC8-64 blade set to FAULTY 51 after removal/insertion of that blade in DCX 8510 chassis with diagpost on Symptom: May see a faulted blade upon insertion due to diagnostics failure. Feature: 16G Platform Services Function: FOS Kernel Drivers Probability: Medium Found in Release: FOS7.0.0 Defect ID: DEFECT000345858 Technical Severity: High Summary: FIPS firmware integrity check has gaps in coverage Symptom: None Feature: FOS-Infrastructure Function: Firmware Download Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000346532 Technical Severity: High Summary: Disable or shutdown BES causes the SVC nodes to go offline and service mode. Symptom: Disable or poweroff BES switch causes the SVC nodes to go offline. The SVC nodes reboot several times before it toggled between offline and services mode. Workaround: Issue affects SVC storage with BES going offline. Restart storage with VI/VT members (BES) online. Feature: FC Services Function: Name Server Probability: High Found in Release: FOS7.0.0 Fabric OS v7.0.1b Release Notes v1.0 Page 95 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Fabric OS v7.0.1b Release Notes v1.0
Page 95 of 99
Closed with Code Change in Fabric OS v7.0.0a – GA June 2, 2011
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
June 2, 2011 in Fabric OS v7.0.0a.
Defect ID:
DEFECT000321855
Technical Severity:
High
Summary:
CRC and/or CDR-5021 errors seen on DCX, DCX-4S, or 5100 switch platforms
Symptom:
CRC or other errors as described below: 1. Port 7/0 detected CRC error with good EOF
when FC8-16 is placed in DCX-4s Slot7. For the solution to be effective, one must execute:
serdestunemode --set; 2. Port 7/0, 7/10 detected CRC error when FX8-24 is placed in DCX-
4s slot7. May also see CRC error on corresponding core blade backend port 3/10 6/30.
Solution is effective upon upgrade, hafailover or re-init of blade. 3. 5100 experience CRC
error with 3rd party tape device. 4. FC10-6 in DCX detects backend port with stuck VC after
link level error (CDR-5021)
Feature:
FC10-6 Platform Services
Function:
ASIC Driver
Probability:
Low
Found in Release:
FOS6.3.1
Service Request ID:
451697
Where Else Fixed:
FOS7.0.0 GA
Defect ID:
DEFECT000345259
Technical Severity:
High
Summary:
FC8-64 blade set to FAULTY 51 after removal/insertion of that blade in DCX 8510 chassis
with diagpost on
Symptom:
May see a faulted blade upon insertion due to diagnostics failure.
Feature:
16G Platform Services
Function:
FOS Kernel Drivers
Probability:
Medium
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000345858
Technical Severity:
High
Summary:
FIPS firmware integrity check has gaps in coverage
Symptom:
None
Feature:
FOS-Infrastructure
Function:
Firmware Download
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000346532
Technical Severity:
High
Summary:
Disable or shutdown BES causes the SVC nodes to go offline and service mode.
Symptom:
Disable or poweroff BES switch causes the SVC nodes to go offline. The SVC nodes reboot
several times before it toggled between offline and services mode.
Workaround:
Issue affects SVC storage with BES going offline. Restart storage with VI/VT members
(BES) online.
Feature:
FC Services
Function:
Name Server
Probability:
High
Found in Release:
FOS7.0.0