Dell Force10 S55T S55 Configuration Guide FTOS 8.3.5.3 - Page 685
Table 38-2., Dell Force10 Enterprise-specific SNMP Traps, Command Option
View all Dell Force10 S55T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 685 highlights
Table 38-2. Dell Force10 Enterprise-specific SNMP Traps Command Option envmon supply envmon temperature envmon fan xstp ecfm Trap MINOR_SFM: MInor alarm: No working standby SFM MINOR_SFM_CLR: Minor alarm cleared: Working standby SFM present TASK SUSPENDED: SUSPENDED - svce:%d - inst:%d - task:%s RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR ABNORMAL_TASK_TERMINATION: CRASH - task:%s %s CPU_THRESHOLD: Cpu %s usage above threshold. Cpu5SecUsage (%d) CPU_THRESHOLD_CLR: Cpu %s usage drops below threshold. Cpu5SecUsage (%d) MEM_THRESHOLD: Memory %s usage above threshold. MemUsage (%d) MEM_THRESHOLD_CLR: Memory %s usage drops below threshold. MemUsage (%d) DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d PEM_PRBLM: Major alarm: problem with power entry module %s PEM_OK: Major alarm cleared: power entry module %s is good MAJOR_PS: Major alarm: insufficient power %s MAJOR_PS_CLR: major alarm cleared: sufficient power MINOR_PS: Minor alarm: power supply non-redundant MINOR_PS_CLR: Minor alarm cleared: power supply redundant MINOR_TEMP: Minor alarm: chassis temperature MINOR_TEMP_CLR: Minor alarm cleared: chassis temperature normal (%s %d temperature is within threshold of %dC) MAJOR_TEMP: Major alarm: chassis temperature high (%s temperature reaches or exceeds threshold of %dC) MAJOR_TEMP_CLR: Major alarm cleared: chassis temperature lower (%s %d temperature is within threshold of %dC) FAN_TRAY_BAD: Major alarm: fantray %d is missing or down FAN_TRAY_OK: Major alarm cleared: fan tray %d present FAN_BAD: Minor alarm: some fans in fan tray %d are down FAN_OK: Minor alarm cleared: all fans in fan tray %d are good %SPANMGR-5-STP_NEW_ROOT: New Spanning Tree Root, Bridge ID Priority 32768, Address 0001.e801.fc35. %SPANMGR-5-STP_TOPOLOGY_CHANGE: Bridge port GigabitEthernet 11/38 transitioned from Forwarding to Blocking state. %SPANMGR-5-MSTP_NEW_ROOT_BRIDGE: Elected root bridge for instance 0. %SPANMGR-5-MSTP_NEW_ROOT_PORT: MSTP root changed to port Gi 11/38 for instance 03.276M8y:0B0rdi0d.g0e38IaD.:2c40019.60:0001.e801.fc35 Old Root: 40960:0001.e801.fc35 New Root: %ISnPsAtNaMnGcRe-5I-dMS0TPp_oTrOtPOGLiOG1Y1_/C3H8ANtGrEa:nsTiotpioolnoegdy fcrhoamngfeorBwrairddgienAgddtro: d0i0s0c1a.red8i0n1g.fsct3a5tMes.tp %cEuCsFtMo-m5e-rE1CFaMt_XLCeOvNe_lAL7ARVML:ANCr1o0s0s0 connect fault detected by MEP 1 in Domain %aEtCFLMe-v5e-lEC7FMV_LEARNRO1R0_0A0LARM: Error CCM Defect detected by MEP 1 in Domain customer1 %pErCoFvMi-d5e-rECaFtM_LMeAvCe_lST4ATVULSA_NAL3A0R0M0: MAC Status Defect detected by MEP 1 in Domain %cEuCsFtMo-m5e-rE1CFaMt_RLEeMvOeTlE_7ALVALRAMN:1R0e0m0ote CCM Defect detected by MEP 3 in Domain %LEeCvFeMl-57-EVCLFAMN_R1D0I0_0ALARM: RDI Defect detected by MEP 3 in Domain customer1 at Simple Network Management Protocol | 685