Dell Force10 S55T S55 Configuration Guide FTOS 8.3.5.3 - Page 788
Running Offline Diagnostics on an S-Series Standalone Unit, Running
View all Dell Force10 S55T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 788 highlights
www.dell.com | support.dell.com Figure 46-3. Running Offline Diagnostics on an S-Series Standalone Unit Force10#diag stack-unit 1 alllevels Wtaornsihnugt -didrieacgtnloystciocnneexcetceudtipoonrtwsill cause multiple link flaps on the peer side - advisable Proceed with Diags [confirm yes/no]: yes 00:03:35: %S50N:1 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 1 00:03:35 : Approximate time to complete these Diags ... 6 Min S50N#00:09:32 : Diagnostic test results are stored on file: flash:/TestReport-SU-0.txt 00:09:37: %S50N:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 0 Diags completed... Rebooting the system now!!! [reboot output omitted] S50N#00:01:35: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Configured from console by console dir Directory of flash: 1 drw2 drwx 3 drw4 d--5 -rw6 -rw- 16384 1536 512 512 3854 12632 Jan 01 1980 00:00:00 +00:00 . Feb 29 1996 00:05:22 +00:00 .. Aug 15 1996 23:09:48 +00:00 TRACE_LOG_DIR Aug 15 1996 23:09:52 +00:00 ADMIN_DIR Sep 24 1996 03:43:46 +00:00 startup-config Nov 05 2008 17:15:16 +00:00 TestReport-SU-1.txt flash: 3104256 bytes total (3086336 bytes free) Figure 46-4 shows the output of the master and member units when you run offline diagnostics on a member unit. Figure 46-4. Running Offline Diagnostics on an S-Series Stack Member [output from master unit] Force10#diag stack-unit 2 Warning - the stack unit will be pulled out of the stack for diagnostic execution Proceed with Diags [confirm yes/no]: yes Warning - diagnostic execution will cause multiple link flaps on the peer side - advisable to shut directly connected ports Proceed with Diags [confirm yes/no]: yes Force10#00:03:13: %S25P:2 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 2 00:03:13 : Approximate time to complete these Diags ... 6 Min 0T0e:s0t3R:e1p3or:t-DSiUa-g2n.otsxttic test results will be stored on stack unit 2 file: flash:/ Force10#00:03:35: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 2 down - card removed 00:08:50: %STKUNIT1-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present 00:09:00: %STKUNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from Stack unit 2 (type S25P, 28 ports) 00:09:00: %S25P:2 %CHMGR-0-PS_UP: Power supply 0 in unit 2 is up 00:09:00: %STKUNIT1-M:CP %CHMGR-5-STACKUNITUP: Stack unit 2 is up [output from the console of the unit in which diagnostics are performed] Force10(stack-member-2)# Diagnostic test results are stored on file: flash:/TestReport-SU-2.txt Diags completed... Rebooting the system now!!! 4. View the results of the diagnostic tests using the command show file flash:// from EXEC Privilege mode, as shown in Figure 46-5. 788 | S-Series Debugging and Diagnostics