Electrolux EDW5505E Service Manual - Page 14

Other Parameters - washing machine

Page 14 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL 8. OTHER PARAMETERS dPA Dishwashing Parameters Sym. Parameter Description Unit Min Max Factory Default IPA Initial Pause before start washing (for ALL cycles) [s] 0 10 0 dLY Delay for the 2nd wash pump (PW only) [s] 0 10 3 Pdr Active a drain phase at the end of washing phase. [s] 0 40 0 RPA Duration of pause after rinse cycle (valid for dishwashers with door/hood lock device) [See par. 9.2 Medical line dishwasher with door/hood lock [s] 0 60 0 device]. C F Celsius/Fahrenheit selection 0 = Celsius - 0 1 0 1 = Fahrenheit rit Rinse Temperature Display. Enable rinse temperature probe (if installed). 0 = during rinse phase the display shows boiler temperature; - 0 1 0 1 = during rinse phase the display shows rinse temperature; PPL Pulse Per Litre. This parameter must be settled in according to flow meter installed. [p/l] 0 255 0 CdE Number of wash cycles performable without detergent (only for dishwashers with external detergent level sensor - par. 9.2.1 Detergent - 0 5 5 and rinse aid level sensors activation) [LES=1] 1LE Pressure sensor threshold 1 [present up to software version 2.11]. - 0 255 140 1HS Pressure sensor histeresis 1 [present up to software version 2.11]. - 0 255 50 2LE Pressure sensor threshold 2 [present up to software version 2.11]. - 0 255 140 2Hs Pressure sensor histeresis 2 [present up to software version 2.11]. - 0 255 50 Note: 1LE, 1HS, 2LE, 2HS parameters emulates a two levels pressure switch, keep in mind that value doesn't correspond to a physical quantity. ron Read Only Parameters Sym. Parameter Description Unit rEL Main Board Firmware Release - rLs Water softener board software version. - CAll When CAll message appears, the parameter value becomes 1. After maintenance, to clear CAll message, insert 0. - C 8 When C 8 alarm appears, the machine is frozen and this parameter is 1. After maintenance (see alarm codes document), insert 0 to enable the - machine. F21 This alarm appears in case of malfunctioning in the continuous water softener. To facilitate fault-finding, see par. E "Alarm codes that stop the - machine for models with incorporated continuous water softener". Min Max Factory Default - - - - - - - - - - - - - - - HCP Communication and HACCP Parameters Sym. Parameter Description Unit SEr Serial Device 0 = 8N1 1 = PC connection (DAAS 8E1) 7 = HACCP network (ECAP 8E1+LK485) (LK485 board is necessary) 9 = Dishwashers with incorporated continuous - water softener 16 = HACCP printer (8N1) 32 = MODEM GSM (DAAS 8N1) 33 = MODEM GSM (DAAS 8E1) 48 = Hyper Terminal (8N1) Adr Address. This parameter specifies the address of the appliance into the 'HACCP_network'. - Works only if 'HACCP network' is selected (see above parameter). DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional Min Max Factory Default 0 63 1 0 255 1 P.14/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.14/88
8.
OTHER PARAMETERS
dPA
Dishwashing Parameters
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
IPA
Initial Pause before start washing (for ALL cycles)
[s]
0
10
0
dLY
Delay for the 2
nd
wash pump (PW only)
[s]
0
10
3
Pdr
Active a drain phase at the end of washing phase.
[s]
0
40
0
RPA
Duration of pause after rinse cycle (valid for dishwashers with door/hood
lock device) [See par. 9.2 Medical line dishwasher with door/hood lock
device].
[s]
0
60
0
C F
Celsius/Fahrenheit selection
0 = Celsius
1 = Fahrenheit
-
0
1
0
rit
Rinse Temperature Display.
Enable rinse temperature probe (if installed).
0 =
during rinse phase the display shows boiler temperature;
1 =
during rinse phase the display shows rinse temperature;
-
0
1
0
PPL
Pulse Per Litre.
This parameter must be settled in according to flow meter installed.
[p/l]
0
255
0
CdE
Number of wash cycles performable without detergent (only for
dishwashers with external detergent level sensor – par. 9.2.1 Detergent
and rinse aid level sensors activation) [
LES=1
]
-
0
5
5
1LE
Pressure sensor threshold 1 [present up to software version 2.11].
-
0
255
140
1HS
Pressure sensor histeresis 1 [present up to software version 2.11].
-
0
255
50
2LE
Pressure sensor threshold 2 [present up to software version 2.11].
-
0
255
140
2Hs
Pressure sensor histeresis 2 [present up to software version 2.11].
-
0
255
50
Note:
1LE
,
1HS
,
2LE
,
2HS
parameters emulates a two levels pressure switch, keep in mind that value doesn’t correspond to a
physical quantity.
ron
Read Only Parameters
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
rEL
Main Board Firmware Release
-
-
-
-
rLs
Water softener board software version.
-
-
-
-
CAll
When
CAll
message appears, the parameter value becomes
1
.
After maintenance, to clear
CAll
message, insert
0
.
-
-
-
-
C 8
When
C 8
alarm appears, the machine is frozen and this parameter is
1
.
After maintenance (see alarm codes document), insert 0 to enable the
machine.
-
-
-
-
F21
This alarm appears in case of malfunctioning in the continuous water
softener. To facilitate fault-finding, see par. E "Alarm codes that stop the
machine for models with incorporated continuous water softener".
-
-
-
-
HCP
Communication and HACCP Parameters
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
SEr
Serial Device
0 = 8N1
1 = PC connection
(DAAS 8E1)
7 = HACCP network
(ECAP 8E1+LK485)
(LK485 board is necessary)
9 = Dishwashers with incorporated continuous
water softener
16 = HACCP printer
(8N1)
32 = MODEM GSM
(DAAS 8N1)
33 = MODEM GSM
(DAAS 8E1)
48 = Hyper Terminal (8N1)
-
0
63
1
Adr
Address.
This parameter specifies the address of the appliance into the
‘HACCP_network’.
Works only if ‘HACCP network’ is selected (see above parameter).
-
0
255
1