Electrolux EDW5505E Service Manual - Page 58

WT30M, Prog. 034, WT65M, Prog. 035

Page 58 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL WT30M CY3 Cycle 3 parameters family. Ln3 8 Long Wash Phase [min] Sh3 35 Short Wash Phase [s] pA3 5 Pause [s] ri3 35 Rinse Phase Duration [s] dr3 40 Drain [s] FP3 60 Final Pause at End of Cycle [s]. dPA Set other parameters. rPA 45 Duration of pause after the rinse cycle [s]. C F 1 Fahrenheit. 6. Switch OFF and then switch ON the machine. Prog. 034 WT65M Prog. 035 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP 3 Medical line dishwasher with lock door/hood device. boi 0 Atmospheric boiler. doo 1 Front loading. dFL 3 Default values for Undercounter models. trc 1 SOFT START ENABLED. b_t 1 Tank heater works only if boiler temperature reached. btF 75 Enable filling tank by means of rinsing cycles. LES 0 Detergent level switches not enabled. UI 9 Select user interface hood type model (up to version 3.11 set to 1). rE 0 Regeneration cycle disabled. ALr 1 Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Enter into FAC parameter family and change boiler threshold. bt°C 92 Boiler Temperature Threshold. bHi 0 Disable boiler high Temperature alarm ( C 2 ). bAJ 0 Boiler Temperature Adjust. bSt 0 Booster function not needed. btd 10 During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 65 Tub Temperature Threshold. tHi 85 Tank high Temperature limit. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.58/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.58/88
WT30M
Prog. 034
CY3
Cycle 3 parameters family.
Ln3
8
Long Wash Phase [min]
Sh3
35
Short Wash Phase [s]
pA3
5
Pause [s]
ri3
35
Rinse Phase Duration [s]
dr3
40
Drain [s]
FP3
60
Final Pause at End of Cycle [s].
dPA
Set other parameters.
rPA
45
Duration of pause after the rinse cycle [s].
C F
1
Fahrenheit.
6.
Switch OFF and then switch ON the machine.
WT65M
Prog. 035
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
3
Medical line dishwasher with lock door/hood device.
boi
0
Atmospheric boiler.
doo
1
Front loading.
dFL
3
Default values for Undercounter models.
trc
1
SOFT START ENABLED.
b_t
1
Tank heater works only if boiler temperature reached.
btF
75
Enable filling tank by means of rinsing cycles.
LES
0
Detergent level switches not enabled.
UI
9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
rE
0
Regeneration cycle disabled.
ALr
1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family and change boiler threshold.
bt
°
C
92
Boiler Temperature Threshold.
bHi
0
Disable boiler high Temperature alarm (
C 2
).
bAJ
0
Boiler Temperature Adjust.
bSt
0
Booster function not needed.
btd
10
During stand-by boiler is kept at lower temperature than Temperature Threshold.
tt
°
C
65
Tub Temperature Threshold.
tHi
85
Tank high Temperature limit.