Electrolux EDW5505E Service Manual - Page 86

AL_14, AL_20, AL_21, AL_22, AL_23, AL_24, AL_25

Page 86 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL AL_14 AL_20 AL_21 AL_22 AL_23 AL_24 AL_25 Limit switch combination not allowed: top limit switch (FC_UP) and bottom limit switch (FC_DW) activated at the same time! Limit switch combination not allowed. Appears if one of the following combinations occurs: - top limit switch (S5) and bottom limit switch (S3) both activated (S3 and S5 could be disconnected); - top limit switch S5 and S3'' both cut in; - bottom limit switch (S3) cut in but not S3''. During lifting, the current absorbed by the lifting motor has exceeded the threshold (see parameter Ith): a) excessive mechanical force during lifting. During lowering, the current absorbed by the lifting motor has exceeded the threshold (see parameter Ith): a) excessive mechanical force during lowering. The hood should be stopped but the card detects a high current absorption by the lifting motor: a) the relay RL18/RL19 could be stuck; b) feeder connector CN32 could be disconnected. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.86/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.86/88
AL_14
Limit switch combination not allowed:
top limit switch (FC_UP) and bottom limit
switch (FC_DW) activated at the same time!
Limit switch combination not allowed.
Appears if one of the following
combinations occurs:
- top limit switch (S5) and bottom limit switch (S3) both
activated (S3 and S5
could be disconnected)
;
- top limit switch S5 and S3’’ both cut in;
- bottom limit switch (S3) cut in but not S3’’.
AL_20
During lifting, the current absorbed by the
lifting motor has exceeded the threshold (see
parameter
Ith
):
a) excessive mechanical force during lifting.
-
AL_21
During lowering, the current absorbed by the
lifting motor has exceeded the threshold (see
parameter
Ith
):
a)
excessive mechanical force during
lowering.
-
AL_22
AL_23
AL_24
AL_25
The hood should be stopped but the card
detects a high current absorption by the lifting
motor:
a)
the relay RL18/RL19 could be stuck;
b)
feeder
connector
CN32
could
be
disconnected.
-