Electrolux EDW5505E Service Manual - Page 46

LB5G/WT4G, Prog. 022, ECOTEMP5 EAG, Prog. 023

Page 46 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LB5G/WT4G Prog. 022 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP boi 0 Hood Type like working cycles. 0 Atmospheric boiler. doo dFL trc b_t btF 2 Front loading door type. 3 Default values for Undercounter models. 0 (for this appliance SOFT START is NOT possible). 1 Tank heater works only if boiler temperature reached. 0 The tank is filled into the traditional way. LES UI rE ALr 0 15 0 1 Detergent level switches not enabled. Select user interface for LS5 (up to version 3.11 set to 7). Regeneration cycle disabled. ALARMS ENABLED. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Enter into FAC parameter family. bt°C bAJ bSt 85 0 2 Boiler Temperature Threshold. Boiler Temperature Adjust. Booster Function. 5. Modify the cycle parameters: CY3 Cycle 3 parameters family. Ln3 Sh3 1 40 Long Wash Phase [min] Short Wash Phase [s] 6. Switch OFF and then switch ON the machine. 7. Modify Detergent dosage: GEn Enter into GEn parameter family. dIn rIn 70 5 Initial Detergent Dosage [s]. Initial Rinse Aid Dosage [s]. 8. Switch OFF and then switch ON the machine. ECOTEMP5 EAG Prog. 023 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP 0 Hood Type like working cycles. boi 0 Atmospheric boiler. doo 2 Front loading door type. dFL 3 Default values for Undercounter models. trc 1 SOFT START ENABLED. b_t 1 Tank heater works only if boiler temperature reached. btF 75 Enable filling tank by means of rinsing cycles. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.46/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.46/88
LB5G/WT4G
Prog. 022
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Hood Type like working cycles.
boi
0
Atmospheric boiler.
doo
2
Front loading door type.
dFL
3
Default values for Undercounter models.
trc
0
(for this appliance SOFT START is NOT possible).
b_t
1
Tank heater works only if boiler temperature reached.
btF
0
The tank is filled into the traditional way.
LES
0
Detergent level switches not enabled.
UI
15
Select user interface for LS5
(up to version 3.11 set to
7
)
.
rE
0
Regeneration cycle disabled.
ALr
1
ALARMS ENABLED.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family.
bt
°
C
85
Boiler Temperature Threshold.
bAJ
0
Boiler Temperature Adjust.
bSt
2
Booster Function.
5.
Modify the cycle parameters:
CY3
Cycle 3 parameters family.
Ln3
1
Long Wash Phase [min]
Sh3
40
Short Wash Phase [s]
6.
Switch OFF and then switch ON the machine.
7.
Modify Detergent dosage:
GEn
Enter into GEn parameter family.
dIn
70
Initial Detergent Dosage [s].
rIn
5
Initial Rinse Aid Dosage [s].
8.
Switch OFF and then switch ON the machine.
ECOTEMP5 EAG
Prog. 023
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Hood Type like working cycles.
boi
0
Atmospheric boiler.
doo
2
Front loading door type.
dFL
3
Default values for Undercounter models.
trc
1
SOFT START ENABLED.
b_t
1
Tank heater works only if boiler temperature reached.
btF
75
Enable filling tank by means of rinsing cycles.