Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LS5WS / WT4WS TRIPHASE Prog. 012 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP boi doo dFL trc b_t btF LES UI rE ALr 0 0 2 3 1 1 75 0 13 1 1 Hood Type like working cycles. Atmospheric boiler. Front loading door type. Default values for Undercounter models. SOFT START ENABLED. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface for LS5 (up to version 3.11 set to 5). Regeneration cycle enabled. ALARMS ENABLED. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Enter into FAC parameter family. bt°C bAJ bSt 83 2 2 Boiler Temperature Threshold. Boiler Temperature Adjust. Booster Function. 5. Modify the cycle parameters: CY3 Cycle 3 parameters family. Ln3 Sh3 1 40 Long Wash Phase [min] Short Wash Phase [s] 6. Switch OFF and then switch ON the machine. 7. Modify Detergent dosage: GEn Enter into GEn parameter family. dIn 70 Initial Detergent Dosage [s]. rIn 5 Initial Rinse Aid Dosage [s]. 8. Cnt Counters rCy 20 Number of cycles allowed before regeneration. 9. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.35/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.35/88
LS5WS / WT4WS TRIPHASE
Prog. 012
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Hood Type like working cycles.
boi
0
Atmospheric boiler.
doo
2
Front loading door type.
dFL
3
Default values for Undercounter models.
trc
1
SOFT START ENABLED.
b_t
1
Tank heater works only if boiler temperature reached.
btF
75
Enable filling tank by means of rinsing cycles.
LES
0
Detergent level switches not enabled.
UI
13
Select user interface for LS5
(up to version 3.11 set to
5
)
.
rE
1
Regeneration cycle enabled.
ALr
1
ALARMS ENABLED.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family.
bt
°
C
83
Boiler Temperature Threshold.
bAJ
2
Boiler Temperature Adjust.
bSt
2
Booster Function.
5.
Modify the cycle parameters:
CY3
Cycle 3 parameters family.
Ln3
1
Long Wash Phase [min]
Sh3
40
Short Wash Phase [s]
6.
Switch OFF and then switch ON the machine.
7.
Modify Detergent dosage:
GEn
Enter into GEn parameter family.
dIn
70
Initial Detergent Dosage [s].
rIn
5
Initial Rinse Aid Dosage [s].
8.
Cnt
Counters
rCy
20
Number of cycles allowed before regeneration.
9.
Switch OFF and then switch ON the machine.