Electrolux EDW5505E Service Manual - Page 25

Prog. 002

Page 25 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LS10 Prog. 002 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters: tYP boi doo dFL trc b_t btF LES UI rE ALr 0 0 1 1 0 1 75 0 9 0 1 Hood Type like working cycles. Atmospheric boiler. Manual Hood. Default values for Hood Type models. (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type model (up to version 3.11 set to 1). Regeneration cycle disabled. Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Factory parameters family bt°C 78 Boiler Temperature Threshold. 5. Modify Cycle parameters: CY1 Cycle 1 Sh1 45 Short Wash Phase [s] CY2 Cycle 2 Ln2 Sh2 1 Long Wash Phase [min] 40 Short Wash Phase [s] 6. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.25/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.25/88
LS10
Prog. 002
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters:
tYP
0
Hood Type like working cycles.
boi
0
Atmospheric boiler.
doo
1
Manual Hood.
dFL
1
Default values for Hood Type models.
trc
0
(for this appliance SOFT START is NOT possible).
b_t
1
Tank heater works only if boiler temperature reached.
btF
75
Enable filling tank by means of rinsing cycles.
LES
0
Detergent level switches not enabled.
UI
9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
rE
0
Regeneration cycle disabled.
ALr
1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Factory parameters family
bt
°
C
78
Boiler Temperature Threshold.
5.
Modify Cycle parameters:
CY1
Cycle 1
Sh1
45
Short Wash Phase [s]
CY2
Cycle 2
Ln2
1
Long Wash Phase [min]
Sh2
40
Short Wash Phase [s]
6.