Electrolux EDW5505E Service Manual - Page 45

Ls5 / Wt 4 Pres Mono, Prog. 021

Page 45 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LS5 / WT 4 PRES MONO Prog. 021 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP boi doo dFL trc b_t btF LES UI rE ALr 0 1 2 3 0 1 0 0 15 0 0 Hood Type like working cycles. Pressure boiler. Front loading door type. Default values for Undercounter models. (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. Select user interface without display (up to version 3.11 set to 7). Regeneration cycle disabled. ALARMS NOT ENABLED. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Enter into FAC parameter family. bt°C bAJ bSt 82 3 2 Boiler Temperature Threshold. Boiler Temperature Adjust. Booster Function. 5. Modify the cycle parameters: CY3 Cycle 3 parameters family. Ln3 Sh3 1 Long Wash Phase [min] 40 Short Wash Phase [s] 6. Switch OFF and then switch ON the machine. 7. Modify Detergent dosage: GEn Enter into GEn parameter family. dIn 165 rIn 0 dEt 182 rAi 61 Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when LOAD SOLENOID VALVE in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 8. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.45/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.45/88
LS5 / WT 4 PRES MONO
Prog. 021
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Hood Type like working cycles.
boi
1
Pressure boiler.
doo
2
Front loading door type.
dFL
3
Default values for Undercounter models.
trc
0
(for this appliance SOFT START is NOT possible).
b_t
1
Tank heater works only if boiler temperature reached.
btF
0
The tank is filled into the traditional way.
LES
0
Detergent level switches not enabled.
UI
15
Select user interface without display
(up to version 3.11 set to
7
)
.
rE
0
Regeneration cycle disabled.
ALr
0
ALARMS NOT ENABLED.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family.
bt
°
C
82
Boiler Temperature Threshold.
bAJ
3
Boiler Temperature Adjust.
bSt
2
Booster Function.
5.
Modify the cycle parameters:
CY3
Cycle 3 parameters family.
Ln3
1
Long Wash Phase [min]
Sh3
40
Short Wash Phase [s]
6.
Switch OFF and then switch ON the machine.
7.
Modify Detergent dosage:
GEn
Enter into GEn parameter family.
dIn 165
Initial Detergent Dosage.
rIn
0
Initial Rinse Aid Dosage.
dEt 182
Detergent dispenser works when LOAD SOLENOID VALVE in activated.
rAi
61
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
8.
Switch OFF and then switch ON the machine.