Electrolux EDW5505E Service Manual - Page 30

LS12HD, Prog. 007

Page 30 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LS12HD Prog. 007 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters: tYP boi doo dFL trc b_t btF LES UI rE ALr 0 0 1 1 0 1 75 0 9 0 1 Hood Type like working cycles. Atmospheric boiler. Manual Hood. Default values for Hood Type models. (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type model (up to version 3.11 set to 1). Regeneration cycle disabled. Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify the cycle parameters: CY1 Enter into Cycle 1 parameters family. Pr1 dr1 20 Pre-rinse Duration [s] 36 Drain [s] CY2 Enter into Cycle 2 parameters family. Pr2 dr2 20 Pre-rinse Duration [s] 36 Drain [s] CY3 Enter into Cycle 3 parameters family. Pr3 dr3 20 Pre-rinse Duration [s] 36 Drain [s] 5. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.30/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.30/88
LS12HD
Prog. 007
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters:
tYP
0
Hood Type like working cycles.
boi
0
Atmospheric boiler.
doo
1
Manual Hood.
dFL
1
Default values for Hood Type models.
trc
0
(for this appliance SOFT START is NOT possible).
b_t
1
Tank heater works only if boiler temperature reached.
btF
75
Enable filling tank by means of rinsing cycles.
LES
0
Detergent level switches not enabled.
UI
9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
rE
0
Regeneration cycle disabled.
ALr
1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.
4.
Modify the cycle parameters:
CY1
Enter into Cycle 1 parameters family.
Pr1
20
Pre-rinse Duration [s]
dr1
36
Drain [s]
CY2
Enter into Cycle 2 parameters family.
Pr2
20
Pre-rinse Duration [s]
dr2
36
Drain [s]
CY3
Enter into Cycle 3 parameters family.
Pr3
20
Pre-rinse Duration [s]
dr3
36
Drain [s]
5.
Switch OFF and then switch ON the machine.