Page 56 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL WT38 MED CY3 Cycle 3 parameters family. Ln3 8 Long Wash Phase [min] Sh3 35 Short Wash Phase [s] pA3 5 Pause [s] ri3 35 Rinse Phase Duration [s] dr3 40 Drain [s] FP3 60 Final Pause at End of Cycle [s]. dPA Set other parameters. rPA 45 Duration of pause after the rinse cycle [s]. 6. Switch OFF and then switch ON the machine. Prog. 032 LS6MCD Prog. 033 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP 0 Hood Type like working cycles. boi 0 Atmospheric boiler. doo 2 Front loading. dFL 3 Default values for Undercounter models. trc 1 SOFT START ENABLED. b_t 1 Tank heater works only if boiler temperature reached. btF 75 Enable filling tank by means of rinsing cycles. LES 1 Detergent level switches enabled. UI 9 Select user interface hood type model (up to version 3.11 set to 1). rE 0 Regeneration cycle disabled. ALr 1 Alarms enabled. 3. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.56/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.56/88
WT38 MED
Prog. 032
CY3
Cycle 3 parameters family.
Ln3
8
Long Wash Phase [min]
Sh3
35
Short Wash Phase [s]
pA3
5
Pause [s]
ri3
35
Rinse Phase Duration [s]
dr3
40
Drain [s]
FP3
60
Final Pause at End of Cycle [s].
dPA
Set other parameters.
rPA
45
Duration of pause after the rinse cycle [s].
6.
Switch OFF and then switch ON the machine.
LS6MCD
Prog. 033
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Hood Type like working cycles.
boi
0
Atmospheric boiler.
doo
2
Front loading.
dFL
3
Default values for Undercounter
models.
trc
1
SOFT START ENABLED.
b_t
1
Tank heater works only if boiler temperature reached.
btF
75
Enable filling tank by means of rinsing cycles.
LES
1
Detergent level switches enabled.
UI
9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
rE
0
Regeneration cycle disabled.
ALr
1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.