ECOTEMP 5, Prog. 016

Page 40 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL ECOTEMP 5 Prog. 016 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP boi doo dFL trc b_t 0 Hood Type like working cycles. 0 Atmospheric boiler. 2 Front loading. 3 Default values for Undercounter models. 1 SOFT START ENABLED. 0 Tank and boiler heaters work simultaneously. btF LES UI rE ALr 75 0 8 0 1 Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled (up to version 3.11 set to 0). Regeneration cycle disabled. Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Enter into FAC parameter family and change boiler threshold. bt°C btd 77 3 Boiler Temperature Threshold. During stand-by boiler is kept at lower temperature than Temperature Threshold. 5. Modify the cycle parameters: CY1 Cycle 1 parameters family. Ln1 Sh1 ri1 1 Long Wash Phase [min] 10 Short Wash Phase [s] 25 Rinse Phase Duration [s] dr1 FP1 40 Drain [s] 4 Final Pause [s] CY2 Cycle 2 parameters family. Ln2 Sh2 ri2 dr2 2 Long Wash Phase [min] 22 Short Wash Phase [s] 25 Rinse Phase Duration [s] 40 Drain [s] FP2 4 Final Pause [s] CY3 Cycle 3 parameters family. Ln3 Sh3 ri3 dr3 FP3 4 Long Wash Phase [min] 22 Short Wash Phase [s] 25 Rinse Phase Duration [s] 40 Drain [s] 4 Final Pause [s] drn Drain parameters family. Idr 30 Initial Drain Phase Duration [s] dPA Set other parameters. IPA 5 Initial Pause [s] 6. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.40/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.40/88
ECOTEMP 5
Prog. 016
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Hood Type like working cycles.
boi
0
Atmospheric boiler.
doo
2
Front loading.
dFL
3
Default values for Undercounter
models.
trc
1
SOFT START ENABLED.
b_t
0
Tank and boiler heaters work simultaneously.
btF
75
Enable filling tank by means of rinsing cycles.
LES
0
Detergent level switches not enabled.
UI
8
ACTIVE function disabled
(up to version 3.11 set to
0
)
.
rE
0
Regeneration cycle disabled.
ALr
1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family and change boiler threshold.
bt
°
C
77
Boiler Temperature Threshold.
btd
3
During stand-by boiler is kept at lower temperature than Temperature Threshold.
5.
Modify the cycle parameters:
CY1
Cycle 1 parameters family.
Ln1
1
Long Wash Phase [min]
Sh1
10
Short Wash Phase [s]
ri1
25
Rinse Phase Duration [s]
dr1
40
Drain [s]
FP1
4
Final Pause [s]
CY2
Cycle 2 parameters family.
Ln2
2
Long Wash Phase [min]
Sh2
22
Short Wash Phase [s]
ri2
25
Rinse Phase Duration [s]
dr2
40
Drain [s]
FP2
4
Final Pause [s]
CY3
Cycle 3 parameters family.
Ln3
4
Long Wash Phase [min]
Sh3
22
Short Wash Phase [s]
ri3
25
Rinse Phase Duration [s]
dr3
40
Drain [s]
FP3
4
Final Pause [s]
drn
Drain parameters family.
Idr
30
Initial Drain Phase Duration [s]
dPA
Set other parameters.
IPA
5
Initial Pause [s]
6.