Electrolux EDW5505E Service Manual - Page 71
LU700A / WTU40A, Prog. 047, FL620WS / LV6WS / WT38WS, Prog. 048
View all Electrolux EDW5505E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LU700A / WTU40A CY2 Cycle 2 parameters family. Ln2 1 Long Wash Phase [min] Sh2 10 Short Wash Phase [s] CY3 Cycle 3 parameters family. Ln3 4 Long Wash Phase [min] 6. Switch OFF and then switch ON the machine. Prog. 047 FL620WS / LV6WS / WT38WS Prog. 048 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP 0 Undercounter like working cycles. boi 0 Atmospheric boiler. doo 2 Front loading. dFL 3 Default values for Undercounter models. trc 1 SOFT START ENABLED. b_t 1 Tank heater works only if boiler temperature reached. btF 75 Enable filling tank by means of rinsing cycles. LES 0 Detergent level switches not enabled. UI 8 ACTIVE function disabled (up to version 3.11 set to 0). rE 0 Regeneration cycle disabled (only for dishwashers with non-continuous water softener). ALr 1 Alarms enabled. 3. Modify Communication and HACCP parameters: HCP Enter into HCP parameter family and set the following parameters. sEr 9 Dishwasher with incorporated continuous water softener. 4. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.71/88