Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LU700A / WTU40A CY2 Cycle 2 parameters family. Ln2 1 Long Wash Phase [min] Sh2 10 Short Wash Phase [s] CY3 Cycle 3 parameters family. Ln3 4 Long Wash Phase [min] 6. Switch OFF and then switch ON the machine. Prog. 047 FL620WS / LV6WS / WT38WS Prog. 048 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP 0 Undercounter like working cycles. boi 0 Atmospheric boiler. doo 2 Front loading. dFL 3 Default values for Undercounter models. trc 1 SOFT START ENABLED. b_t 1 Tank heater works only if boiler temperature reached. btF 75 Enable filling tank by means of rinsing cycles. LES 0 Detergent level switches not enabled. UI 8 ACTIVE function disabled (up to version 3.11 set to 0). rE 0 Regeneration cycle disabled (only for dishwashers with non-continuous water softener). ALr 1 Alarms enabled. 3. Modify Communication and HACCP parameters: HCP Enter into HCP parameter family and set the following parameters. sEr 9 Dishwasher with incorporated continuous water softener. 4. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.71/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.71/88
LU700A / WTU40A
Prog. 047
CY2
Cycle 2 parameters family.
Ln2
1
Long Wash Phase [min]
Sh2
10
Short Wash Phase [s]
CY3
Cycle 3 parameters family.
Ln3
4
Long Wash Phase [min]
6.
Switch OFF and then switch ON the machine.
FL620WS / LV6WS / WT38WS
Prog. 048
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Undercounter like working cycles.
boi
0
Atmospheric boiler.
doo
2
Front loading.
dFL
3
Default values for Undercounter models.
trc
1
SOFT START ENABLED.
b_t
1
Tank heater works only if boiler temperature reached.
btF
75
Enable filling tank by means of rinsing cycles.
LES
0
Detergent level switches not enabled.
UI
8
ACTIVE function disabled
(up to version 3.11 set to
0
)
.
rE
0
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
ALr
1
Alarms enabled.
3.
Modify Communication and HACCP parameters:
HCP
Enter into
HCP
parameter family and set the following parameters.
sEr
9
Dishwasher with incorporated continuous water softener.
4.