LS9 / WT 55 ATM, Prog. 018

Page 42 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LS9 / WT 55 ATM Prog. 018 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP boi doo dFL trc b_t btF LES UI rE ALr 0 0 1 1 0 1 75 0 9 0 1 Hood Type like working cycles. Atmospheric boiler. Manual Hood. Default values for Hood Type models. (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type model (up to version 3.11 set to 1). Regeneration cycle disabled. Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Enter into FAC parameter family and change boiler threshold. bt°C bAJ 82 0 Boiler Temperature Threshold. Boiler Temperature Adjust. bSt 1 Booster Function. 5. Modify the cycle parameters: CY2 Cycle 2 parameters family. Sh2 55 Short Wash Phase [s] CY3 Cycle 3 parameters family. Ln3 4 Long Wash Phase [min] dPA Set other parameters. IPA 5 Initial Pause [s] 6. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.42/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.42/88
LS9 / WT 55 ATM
Prog. 018
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Hood Type like working cycles.
boi
0
Atmospheric boiler.
doo
1
Manual Hood.
dFL
1
Default values for Hood Type models.
trc
0
(for this appliance SOFT START is NOT possible).
b_t
1
Tank heater works only if boiler temperature reached.
btF
75
Enable filling tank by means of rinsing cycles.
LES
0
Detergent level switches not enabled.
UI
9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
rE
0
Regeneration cycle disabled.
ALr
1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family and change boiler threshold.
bt
°
C
82
Boiler Temperature Threshold.
bAJ
0
Boiler Temperature Adjust.
bSt
1
Booster Function.
5.
Modify the cycle parameters:
CY2
Cycle 2 parameters family.
Sh2
55
Short Wash Phase [s]
CY3
Cycle 3 parameters family.
Ln3
4
Long Wash Phase [min]
dPA
Set other parameters.
IPA
5
Initial Pause [s]
6.