Electrolux EDW5505E Service Manual - Page 85

AL_10, AL_11, AL_12, AL_13

Page 85 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL AL_5 AL_6 AL_7 AL_8 AL_9 AL_10 AL_11 AL_12 AL_13 (Polarity/motor rotation direction inverted?!). Appears if the bottom limit switch (S3) cuts in during lifting. On installation this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board. TIMEOUT- The time taken for hood lifting was more than the time fixed by parameter t_2 : a) check that the motor works. TIMEOUT- The time taken for lifting was more than the time fixed by parameter t 2. Check correct operation of the: a) motor (thermal protection N7); b) top limit switch (S5 and S5'). The hood is open but the bottom limit switch (FC_DW) has cut in. Appears with hood fully open, if: - the limit switch (S5) returns to the rest position; - the bottom limit switch (S3) cuts in; - S3'' cuts in. Appears if with hood fully open the "door closed" microswitch cuts in. Appears if with hood fully open the "door closed" microswitch cuts in. - S5 could be disconnected. During lowering, the top limit switch (FC_UP) has not returned to the rest position. The limit switch must return to the rest position within a time given by parameter t_6: a) check that the motor works; b) (Polarity/motor rotation direction inverted?!). b 3 During the initial lowering phase the top limit switch (S5) must return to the rest position within a time given by the parameter t_6 otherwise the alarm b 3 appears. - S5 could be stuck. - S3' could be disconnected. On installation, this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board. - Appears if the bottom limit switch S3 cuts in before S3" during lowering. Appears if the top limit switch (FC_UP) cuts in during lowering. (Polarity/motor rotation direction inverted?!). b 3 Appears if the top limit switch (S5) cuts in during lowering. On installation, this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board. TIMEOUT- The time taken for hood closing was more than the time fixed by parameter t_2 : a) check that the motor works. - - TIMEOUT- The time taken for lowering was more than the time fixed by parameter t_2. - S3' could be disconnected. Appears during hood lowering if, after S3'' cuts in, the bottom limit switch S3 does not cut in within the time fixed by parameter t 3. The two hand safety contacts K and K' must be both closed or both open. If this does not occur the alarm appears. - One of the two relays (K or K') could be stuck or disconnected. (See parameter t 4) DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.85/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.85/88
(Polarity/motor rotation direction inverted?!).
Appears if the bottom limit switch (S3) cuts in during
lifting.
On installation this alarm can occur due to incorrect
sequence of the phases: invert the two phases on the
power supply terminal board.
AL_5
TIMEOUT-
The time taken for hood lifting was
more than the time fixed by parameter
t_2
:
a) check that the motor works.
TIMEOUT-
The time taken for lifting was more than the
time fixed by parameter
t 2
.
Check correct operation of the:
a) motor (thermal protection N7);
b) top limit switch (S5 and S5’).
AL_6
The hood is open but the bottom limit switch
(FC_DW) has cut in.
Appears with hood fully open, if:
- the limit switch (S5) returns to the rest position;
- the bottom limit switch (S3) cuts in;
- S3’’ cuts in.
AL_7
Appears if with hood fully open the "door
closed" microswitch cuts in.
Appears if with hood fully open the "door closed"
microswitch cuts in.
- S5 could be disconnected.
AL_8
During lowering, the top limit switch (FC_UP)
has not returned to the rest position.
The limit switch must return to the rest position
within a time given by parameter
t_6
:
a) check that the motor works;
b) (Polarity/motor rotation direction inverted?!).
b 3
During the initial lowering phase the top limit switch
(S5) must return to the rest position within a time given
by the parameter
t_6
otherwise the alarm
b 3
appears.
- S5 could be stuck.
- S3’ could be disconnected.
On installation, this alarm can occur due to incorrect
sequence of the phases: invert the two phases on the
power supply terminal board.
AL_9
-
Appears if the bottom limit switch S3 cuts in before S3"
during lowering.
AL_10
Appears if the top limit switch (FC_UP) cuts in
during lowering.
(Polarity/motor rotation direction inverted?!).
b 3
Appears if the top limit switch (S5) cuts in during
lowering.
On installation, this alarm can occur due to incorrect
sequence of the phases: invert the two phases on the
power supply terminal board.
AL_11
TIMEOUT-
The time taken for hood closing
was more than the time fixed by parameter
t_2
:
a) check that the motor works.
TIMEOUT-
The time taken for lowering was more than
the time fixed by parameter
t_2
.
- S3’ could be disconnected.
AL_12
-
Appears during hood lowering if, after S3’’ cuts in, the
bottom limit switch S3 does not cut in within the time
fixed by parameter
t 3
.
AL_13
-
The two hand safety contacts K and K'
must be both closed or both open. If this
does not occur the alarm appears.
- One of the two relays (K or K’) could be stuck or
disconnected.
(See parameter
t 4
)