WT65MED, Prog. 010
View all Electrolux EDW5505E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL WT65MED Prog. 010 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters: tYP boi doo dFL trc b_t btF LES UI rE ALr 0 0 0 1 0 1 75 0 9 0 1 Hood Type like working cycles. Atmospheric boiler. Automatic Hood. Default values for Hood Type models. (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type model (up to version 3.11 set to 1). Regeneration cycle disabled. Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Factory parameters family bt°C bHi bAJ bSt tHi 90 0 0 0 85 Boiler Temperature Threshold. Disable boiler high Temperature alarm ( C 2 ). Boiler Temperature Adjust. Booster Function. Tank high Temperature limit. 5. Modify the cycle parameters: CY1 Cycle 1 parameters family. Ln1 Sh1 ri1 dr1 2 Long Wash Phase [min] 32 Short Wash Phase [s] 35 Rinse Phase Duration [s] 40 Drain [s] FP1 15 Final Pause [s] CY2 Cycle 2 parameters family. Ln2 Sh2 ri2 dr2 FP2 3 Long Wash Phase [min] 32 Short Wash Phase [s] 35 Rinse Phase Duration [s] 40 Drain [s] 15 Final Pause [s] CY3 Cycle 3 parameters family. Ln3 Sh3 ri3 dr3 FP3 5 Long Wash Phase [min] 32 Short Wash Phase [s] 35 Rinse Phase Duration [s] 40 Drain [s] 15 Final Pause [s] DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.33/88