Electrolux EDW5505E Service Manual - Page 36

LS6 PRESS, Prog. 013

Page 36 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LS6 PRESS Prog. 013 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP boi doo dFL trc b_t btF LES UI rE ALr 0 Hood Type like working cycles. 1 Pressure boiler. 2 Front loading. 3 Default values for Undercounter models. 1 SOFT START ENABLED. 1 Tank heater works only if boiler temperature reached. 0 The tank is filled into the traditional way. 0 Detergent level switches not enabled. 8 ACTIVE function disabled (up to version 3.11 set to 0). 0 Regeneration cycle disabled. 1 Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Enter into FAC parameter family and change boiler threshold. bt°C 86 Boiler Temperature Threshold. 5. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.36/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.36/88
LS6 PRESS
Prog. 013
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP
0
Hood Type like working cycles.
boi
1
Pressure boiler.
doo
2
Front loading.
dFL
3
Default values for Undercounter
models.
trc
1
SOFT START ENABLED.
b_t
1
Tank heater works only if boiler temperature reached.
btF
0
The tank is filled into the traditional way.
LES
0
Detergent level switches not enabled.
UI
8
ACTIVE function disabled
(up to version 3.11 set to
0
)
.
rE
0
Regeneration cycle disabled.
ALr
1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family and change boiler threshold.
bt
°
C
86
Boiler Temperature Threshold.
5.
Switch OFF and then switch ON the machine.