Haier 3U19FS1ERA Service Manual - Page 134
ÛÈäÝ, ÉãÒ, ØÝãáÜØ, ÜÑÛÝÚ, ÉÑáÜÝÚ, ÈÒÖÈÉÉ, ÜÑÛÝ
View all Haier 3U19FS1ERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
>_]]VbTZR\ _^UZdZ_^Vb Present time setting The timing is based on the real time. Thus, the real time should be regulated in advance. The clock regulation steps are as follows: MODE FAN HIGH OPERATION HEAT C ROOM TEMP. CLOCK UP MODE FAN SWING HEALTH TEMP CLOCK TIME TIMER SET RECOVERY CHECK FILTER RESET ON/OFF 1.Press "CLOCK" switch "CLOCK" flickers, and the time displayed is the real time. 2.Press " " and " " to regulate the time. The time increases a minute each time you press " " switch. The time decreases a minute each time you press " " switch. 3.Press "setting" switch. The setting is achieved. Notes If not in timing, the screen displays the real time. If in timing, the screen displays the timing time. If you want to know the real time, go to the first step. 132 Setting of power failure compensation function When SW1-6 on PCB of wire controller is OFF, it will be in power failure compensation. If the SW1-6 is ON, it has no compensation function. When the power is on after blackout, the unit will return to the former state if compensation function is set. Otherwise, it will stop. When restarting the unit, press "ON/OFF" switch on wired controller.