Haier 3U19FS1ERA Service Manual - Page 91
Sign definition, Dry operation, Fan operation, Auto operation, Abnormal operation
View all Haier 3U19FS1ERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
>_]]VbTZR\ _^UZdZ_^Vb 2. Sign definition: Indoor Tai Tc1 Tc2 Ambient temp. Outlet pipe temp. Inlet pipe temp. Tcomp1,2 Temp. compensation Tm mid coil temp. Tset Set temp. Tao Ambient temp. Toci Thick pipe of heat exchanger outdoor Tc Te mid condenser temp. Defrost temp. Ts Compressor suction temp. Td Compressor discharging temp. 3. Dry operation Tai<16℃, indoor unit stops running and sends stop-unit signal to outdoor. Tai≤Tset, indoor motor runs at low speed and sends stop-unit signal to outdoor. 4. Fan operation Indoor fan motor will run as the fan speed set on the remote controller or the wired controller and indoor unit will send the stop-unit signal to outdoor. 5. Auto operation 5.1 If the unit enters Auto mode for the first time, the system will adjust the operation mode according to the room temp. and the set temp. When Tai≥Tset, entering auto cooling mode; When Tai<Tset, entering auto heating mode. 5.2 Auto cooling mode is as the same as the cooling mode. After the thermostat is OFF for 15 minutes, if Tai+ 1+Tcomp2<Tset, the unit will enter auto heating mode, or the unit will still stay at auto cooling mode and stop when it reaches the set temperature; while the indoor motor will be at low speed. 5.3 Auto heating mode is as the same as the heating mode. After the thermostat is OFF for 15 minutes, if Tai≥Tset+1 +Tcomp1, the unit will enter auto cooling mode, or the unit will still stay at auto heating mode; 5.4 In this mode, the Sleep function is available, run as cooling sleep in cooling mode and as heating sleep in heating mode. Once sleep mode is set, the mode will not change after the unit stops for 15 minutes when it arrives Tset. 5.5 Mode conversion will be confirmed after compressor has stopped for 10 minutes. 6. Abnormal operation 6.1 When outdoor modes from the request of indoor unit conflict, the one entering firstly will take priority. 6.2 After indoor receives the ON command from wired controller, it will firstly confirm the outdoor current operation mode. If they are the same modes, indoor unit will run as the request of remote controller. If they are different modes, the system will forbid to operate, and indoor will keep the OFF mode and send the "standby" signal to wired controller until outdoor stops or outdoor mode the requested mode of wired controller are the same, the unit will run as the requested mode of wired controller. 6.3 After indoor receives the ON command from remote controller, it will firstly confirm the outdoor current operation mode. If they are the same mode, indoor unit will run as the request of remote controller. If they are different modes, the system will forbid to operate, and indoor will keep the OFF mode. After setting on remote controller, if the buzzer sounds two times, that shows abnormal operation. Indoor will run until the outdoor mode and the requested mode of remote controller are the same. -90-