>_]]VbTZR\ _^UZdZ_^Vb Item Model AC24CS1ERA Function cooling heating Capacity kW 6.3(2.0--7.3) 7.1(2.5--8.0) Sensible heat ratio 0.72 / Dehumidifying capacity 10‐³×m³/h 2.0 Power Supply 1PH,220-230V 50-60HZ Type × Number CENTRIFUGALX2 Fan Speed(H-M-L) Fan motor output power r/min kW 1220±40/1190±50/1050±50/980±50 0.10 Air-flow(H-M-L) m³/h 800/720/650 Type / Diameter mm inner grooved pipe/φ7 Indoor unit Heat exchanger Total Area m² 0.49 Temp. scope ℃ 2-7 Dimension External (L×W×H) Package (L×W×H) mm×mm×mm mm×mm×mm 990*655*199 1150*750*300 Drainage pipe (material , I.D./O.D.) mm PVC 18/20 Control type (Remote /wired) Remote,.YR-HD Noise level ---sound presure (H-M-L) dB(A) 48/46/44 Noise level ---sound power (H-M-L) dB(A) 59/57/55 Weight (Net / Shipping) kg / kg 28.3/34.3 Refrigerant Type R410A PIPING Pipe Liquid Gas mm 9.52 mm 15.88 Connecting Method flared Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃ DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. -19-