Haier 3U19FS1ERA Service Manual - Page 85
SV2 ON & 20HZ
View all Haier 3U19FS1ERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
>_]]VbTZR\ _^UZdZ_^Vb ·When unit stops, the reason that system still checks the low pressure : in a long time stop, make protection for the compressor on the condition of great refrigerant leakage. ·The reason that low pressure switch action time is 30 seconds: when compressor stops, low pressure does not change, so it will be shorter than the set time in operation. (3) When compressor starts up, in 8 minutes, low pressure switch signal will be shielded. (4) In defrosting, low pressure switch will be shielded. (5) In oil return procedure, low pressure switch will be shielded. (6) In the refrigerant discharging procedure after the oil return in cooling is over, low pressure switch will be shielded. In addition, the system will control low pressure through the evaporator temp. TE to realize the low pressure protection function. In cooling, confirm through Tc2AVE: TinAVE -25℃ -30℃ -35℃ -40℃ -45℃ In heating, confirm through defrosting temp. Te: Normal operation Min. running FQY 20HZ SV2 OFF & 20HZ SV2 ON & 20HZ Keep for 5 seconds, unit stops and alarm occurs. 3 minutes later, restart up. If it occurs 3 times in 1 hour, it will always alarm and stop, electrify again and failure will be cleared. Te -30℃ -35℃ -40℃ -45℃ -50℃ Normal operation Min. running FQY 20HZ SV2 OFF & 20HZ SV2 ON & 20HZ Keep for 5 seconds, unit stops and alarm occurs. 3 minutes later, restart up. If it occurs 3 times in 1 hour, it will always alarm and stop, electrify again and failure will be cleared. If the failure is not confirmed as the permanent protection, outdoor will not send failure code to indoor, and indoor will not alarm. -84-