Haier 3U19FS1ERA Service Manual - Page 15
Pb-700ib, White, Ab18cs1era
View all Haier 3U19FS1ERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
>_]]VbTZR\ _^UZdZ_^Vb Item Model AB18CS1ERA Function cooling heating Capacity kW 5.0(1.8--5.8) 5.2(2.0--6.5) Sensible heat ratio 0.71 / Dehumidifying capacity 10‐³×m³/h 1.8 Power Supply 1PH,220-230V 50-60HZ Type × Number CENTRIFUGALX1 Fan Speed(H-M-L) Fan motor output power r/min kW 795/690/550±50 0.065 Air-flow(H-M-L) m³/h 680/620/500 Type / Diameter mm inner grooved pipe/φ7 Indoor unit Heat exchanger Total Area m² 0.272 Temp. scope ℃ 2-7 Dimension External (L×W×H) Package (L×W×H) mm×mm×mm mm×mm×mm 570/570/260 718*680*380 Drainage pipe (material , I.D./O.D.) mm PVC 26/32 Control type (Remote /wired) Remote,.YR-HD Fresh air hole dimension mm 56 Noise level ---sound presure (H-M-L) dB(A) 42/37/35 Noise level ---sound power (H-M-L) dB(A) 53/48/46 Weight (Net / Shipping) kg / kg 18.5/23 Panel model (color) PB-700IB(WHITE) PIPING Panel Dimension External (L×W×H) mm×mm×mm Package (L×W×H) mm×mm×mm 700*700*60 740*750*115 Weight (Net / Shipping) kg / kg 3.5/4.5 Refrigerant Type R410A Pipe Liquid Gas mm 6.35 mm 12.7 Connecting Method flared Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃ DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. -15-