>_]]VbTZR\ _^UZdZ_^Vb Item Model AB24ES1ERA Function cooling heating Capacity kW 6.5(2.0--7.3) 7.1(2.5--8.0) Sensible heat ratio 0.72 / Dehumidifying capacity 10‐³×m³/h 2.5 Power Supply 1PH,220-230V 50-60HZ Type × Number CENTRIFUGALX1 Fan Speed(H-M-L) Fan motor output power r/min kW 670±40/550±50/460±50 0.16 Air-flow(H-M-L) m³/h 1300/1100/870 Type / Diameter mm inner grooved pipe/φ7 Indoor unit Heat exchanger Total Area m² 0.49 Temp. scope ℃ 2-7 Dimension External (L×W×H) Package (L×W×H) mm×mm×mm mm×mm×mm 840*840*240 910*910*300 Drainage pipe (material , I.D./O.D.) mm PVC 26/32 Control type (Remote /wired) Remote,.YR-HD Fresh air hole dimension mm none Noise level ---sound presure (H-M-L) dB(A) 46/43/36 Noise level ---sound power (H-M-L) dB(A) 57/54/48 Weight (Net / Shipping) kg / kg 26.8/32.6 Panel model (color) PB-950JB(WHITE) PIPING Panel Dimension External (L×W×H) mm×mm×mm Package (L×W×H) mm×mm×mm 950/950/80 985/985/115 Weight (Net / Shipping) kg / kg 6.0/9.0 Refrigerant Type R410A Pipe Liquid Gas mm 9.52 mm 15.88 Connecting Method flared Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃ DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. -18-