HP BL10e HP ProLiant BL e-Class System Setup and Installation Guide - Page 108
Table D-2, Is the Power LED on Both Power Supplies Solid Green?, Answer, Possible Reasons
UPC - 808736933599
View all HP BL10e manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
Troubleshooting Table D-2: Is the Power LED on Both Power Supplies Solid Green? continued Answer Possible Reasons Possible Solutions No, one is green and one is off. One power supply is not connected to AC power or no AC power is available. Be sure that the power cord is connected to the power supply. You still have adequate power, but no redundancy; go on to Table D-3. No, they are both blinking green. Both power supplies are in standby mode. Be sure that the power cord is plugged into a working, grounded outlet. You still have adequate power, but no redundancy; go on to Table D-3. Press the enclosure power button on the redundant fan cage in the rear of the enclosure. Caution: Pressing the enclosure power button while the enclosure is running shuts down the enclosure and all server blades. Be sure that the pins on the power supplies are not damaged. Be sure that the power supplies are fully seated in the power supply bays. No, one is solid green and one is blinking green. One power supply is in standby mode. Yes Be sure that the pins on the power supplies are not damaged. You still have adequate power, but no redundancy; go on to Table D-3. Be sure that the power supplies are fully seated in the power supply bays. You still have adequate power, but no redundancy; go on to Table D-3. If both power LEDs are solid green, go to table D-3. D-6 HP ProLiant BL e-Class System Setup and Installation Guide