HP StorageWorks 2/16V HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 I - Page 101
EN 61000-3-2 Limits for Harmonic Current Emissions, IEC 61000-4-4 Severity Level 3 for Fast Transients
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
Table 26 General specifications (continued) Specification Description EMC immunity • IEC 61000-4-2 Severity Level 3 for Electrostatic Discharge • IEC 61000-4-3 Severity Level 3 for Radiated Fields • IEC 61000-4-4 Severity Level 3 for Fast Transients • IEC 61000-4-5 Severity Level 3 for Surge Voltage • IEC 61000-4-6 Conducted Emissions • IEC 61000-4-11 Voltage Variations • EN 61000-4-12 Oscillatory Waves Immunity • EN 61000-3-2 Limits for Harmonic Current Emissions • EN 61000-3-3 JEIDA System architecture Nonblocking shared-memory switch System processor for the 2/8V, 2/16V and 2/16N PPC405GP, 200 MHz CPU System processor for the 4/32 PowerPC 440GP, 400 MHz CPU ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and Signalling Interface standard) Modes of operation for the 2/8V, 2/16V and 2/16N Fibre Channel Class 2, Class 3 and Class F Modes of operation for the 4/32 Fibre Channel Class 2 and Class 3 Fabric initialization for the 2/8V, 2/16V and 2/16N Complies with FC-SW 5.0 Fabric initialization for the 4/32 Complies with FC-SW-3 Rev. 6.6 FC-IP (IP over Fibre Channel) Complies with FC-IP 2.3 of FCA profile Aggregate switch I/O bandwidth for the 2/8V, 2/16V and 2/16N 64 Gb/s if all 16 ports are running at 2Gb/s, full duplex SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide 101