HP StorageWorks 2/16V HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 I - Page 52
Connecting the serial cable to a SAN Switch 2/16V
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
NOTE: Figure 17 shows the SAN Switch 2/16V. This procedure is the same for all SAN Switches. 100-240 VAC 1.0A 47-63Hz IOIOI ! 100-240 VAC 1.0A 47-63Hz 0014a Figure 17 Connecting the serial cable to a SAN Switch 2/16V NOTE: If the serial port on the workstation uses an RJ-45 connector instead of an RS-232, remove the adapter on the end of the serial cable and insert the exposed RJ-45 connector into the RJ-45 serial port on the workstation. 3. Disable any serial communication programs running on the workstation. 4. Open a terminal emulator application (such as HyperTerminal on a PC or TERM in a UNIX environment) and configure the application as follows: • In a Windows 95, 98, 2000, or NT environment: Bits per second Databits Parity Stop bits Flow control 9600 8 None 1 None • In a UNIX environment, type the following string at the prompt: tip /dev/ttyb -9600 52 Installing and configuring