HP StorageWorks 2/16V HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 I - Page 75
Table 19 Nonport side LED patterns during normal operation
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Table 19 describes the nonport side LEDs. .Table 19 Nonport side LED patterns during normal operation LED name LED color Status of hardware Recommended action Power Supply No light Status Power supply is not receiving power or is off. Verify that the power supply is on and seated and the power cord is connected to a functioning power source. Steady green Power supply is operating normally. No action required. Steady amber (for more than five seconds) Power supply fault for one of the following reasons: • power cable is disconnected • power supply is off • the power supply has failed Try the following: • check the power cable connection • verify that the power supply is powered on • replace the power supply Fan Status No light Fan assembly is not receiving No action required. power. Steady green Fan assembly is operating normally. No action required. Steady amber (for more than five seconds) Fan fault for one of the following reasons: • one or more of the fan(s) in the fan assembly has failed • the fan FRU was disabled by the user Verify that the fan FRU is enabled. If the fan FRU is enabled, the FRU is faulty and should be replaced. SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide 75