35 FW-1427 Recommended Replace the faulty or missing power supply. Action Severity WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty power supply. Action Severity WARNING FW-1428 Message , [FW-1428], ,, WARNING, , Switch status change contributing factor Power supply: absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the missing power supply. Action Severity WARNING FW-1429 Message , [FW-1429], ,, WARNING, , Switch status change contributing factor: Power supplies are not redundant. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the power supplies are not in the correct slots for redundancy. Recommended Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them Action redundant. Severity WARNING Fabric OS Message Reference 289 53-1001157-01